Short slab panels

Test an 11-foot panel with a shorter restraint length.

Design readout

Stiffness ℓ
38.59
in
Wheel stress
159.35
psi
Curl stress
49.49
psi
Stress ratio
0.321

Wheel positions on a jointed slab

Wheel positions on a jointed slabSLAB PLANWHEEL POSITIONSCORNERINTERIOREDGECORNER139.2 psiINTERIOR104.8 psiEDGE159.4 psi
The plan marks three independent wheel positions. The stress values are load-only.

Below PCA fatigue trigger

PCA screening line at stress ratio 0.45. The second mark indicates 0.55.

Calculation ledger
Contact radius a
5.352 in
Equivalent pressure radius b
5.492 in
Interior wheel stress
104.83 psi
Edge wheel stress
159.35 psi
Corner wheel stress
139.17 psi
Bradbury coefficient Cₓ
0.279
Conservative combined tension
208.85 psi
Indicative PCA repetitions
—

Inputs

Changes update results

Single wheel contact
kip
psi
Concrete slab and support
in
ksi
pci
psi
Thermal gradient
°F
ft
µ/°F

Work through this example

  1. Find effective tire contact radius and slab relative stiffness.
  2. Evaluate the classical elastic wheel stresses at the three slab positions.
  3. Compute signed Bradbury curling and add its magnitude to the largest wheel stress for the fatigue screen.

Increase joint spacing to 16 ft and compare the dimensionless Bradbury coefficient.

This uses a conservative stress envelope on a Winkler foundation. The PCA curve is shown as an indicative screen. Check load spectra, stress location and sign, joint load transfer, erosion and cumulative fatigue separately.

Read the equations and sources