100 V Distributed Line With a 120 W Tap Budget

A distributed music system uses sixteen identical 6 W ceiling taps and 24 W of other taps. Use the 100 V output and estimate drop over a 95 m route.

Inputs

Cable run and speaker
m
°C
Ω
Ω
70 V / 100 V transformer line
W
W
dB

Results

Equivalent transformer load
83.33Ω
Farthest load voltage drop
1.85V
Line amplifier power with reserve
190.19W
Cable loop resistance
1.5742Ω
Speaker insertion loss
2.882dB
Effective damping factor
2.5
Reduction in speaker power
48.51%
16 AWG comparison loss
4.221dB
Amplifier output resistance
0.04Ω
Total line transformer taps
120W
Farthest load delivered power
115.59W
Speaker cable loss by run length
Speaker cable loss by run lengthInsertion loss (dB)0387611415219001.973.955.927.9One-way run (m)14 AWG16 AWG

Dots show the two gauges at the entered length. The model compares speaker power at fixed amplifier terminal voltage.

Distributed transformer-line equivalent
Distributed transformer-line equivalent100 V RMS120 W taps83.33 ΩCable loopFarthest-load drop ≈ 1.854 V

The line diagram combines the transformer taps at the far end of the modeled cable.

Same-run copper wire comparison

GaugeLoop R (Ω)Loss (dB)Power at speaker (%)
14 AWG1.57422.88251.49
16 AWG2.50314.22137.83

Worked calculation

  1. Add transformer taps on the line

    Ptotal = 16 × 6 + 24 = 120 W. Rload = 100² ÷ 120 = 83.333 Ω

  2. Add line amplifier reserve

    Pamp = 120 × 10^(2 ÷ 10) = 190.187 W

What the example shows

120 W at 100 V corresponds to 83.33 Ω when modeled as one combined load. The far-end drop is an estimate with all loads beyond the full run.

Model assumptions

  • Resistance assumes annealed copper with equal outgoing and return lengths. Parallel conductors are counted per leg. Cable loss compares speaker power at a fixed amplifier terminal voltage.
  • Effective damping uses the amp damping factor at its stated reference load to infer amp source resistance. The speaker is modeled as a resistive nominal load.
  • The distributed-line estimate places the combined taps at the far end of the selected cable. Real distributed loads draw current along the route, so voltage drop is location-dependent.