100 V Distributed Line With a 120 W Tap Budget
A distributed music system uses sixteen identical 6 W ceiling taps and 24 W of other taps. Use the 100 V output and estimate drop over a 95 m route.
- One-way cable length
- 95 m
- Cable gauge
- 14 AWG
- Compare with
- 16 AWG
- Parallel conductors per leg
- 1
- Copper temperature
- 20 °C
- Speaker load
- 4 Ω
- Rated amplifier damping factor
- 200
- Amplifier DF reference load
- 8 Ω
- Constant-voltage line
- 100 V
- Equal transformer taps
- 16
- Power per equal tap
- 6 W
- Additional tap total
- 24 W
- Line amplifier reserve
- 2 dB
Results
- Equivalent transformer load
- 83.33Ω
- Farthest load voltage drop
- 1.85V
- Line amplifier power with reserve
- 190.19W
- Cable loop resistance
- 1.5742Ω
- Speaker insertion loss
- 2.882dB
- Effective damping factor
- 2.5
- Reduction in speaker power
- 48.51%
- 16 AWG comparison loss
- 4.221dB
- Amplifier output resistance
- 0.04Ω
- Total line transformer taps
- 120W
- Farthest load delivered power
- 115.59W
Dots show the two gauges at the entered length. The model compares speaker power at fixed amplifier terminal voltage.
The line diagram combines the transformer taps at the far end of the modeled cable.
Same-run copper wire comparison
| Gauge | Loop R (Ω) | Loss (dB) | Power at speaker (%) |
|---|---|---|---|
| 14 AWG | 1.5742 | 2.882 | 51.49 |
| 16 AWG | 2.5031 | 4.221 | 37.83 |
Worked calculation
Add transformer taps on the line
Ptotal = 16 × 6 + 24 = 120 W. Rload = 100² ÷ 120 = 83.333 Ω
Add line amplifier reserve
Pamp = 120 × 10^(2 ÷ 10) = 190.187 W
What the example shows
120 W at 100 V corresponds to 83.33 Ω when modeled as one combined load. The far-end drop is an estimate with all loads beyond the full run.
Model assumptions
- Resistance assumes annealed copper with equal outgoing and return lengths. Parallel conductors are counted per leg. Cable loss compares speaker power at a fixed amplifier terminal voltage.
- Effective damping uses the amp damping factor at its stated reference load to infer amp source resistance. The speaker is modeled as a resistive nominal load.
- The distributed-line estimate places the combined taps at the far end of the selected cable. Real distributed loads draw current along the route, so voltage drop is location-dependent.
Common questions
Does changing the 120 W line from 70.7 to 100 V increase tap watts automatically?
The entered tap totals describe correctly rated transformer settings for the selected line. Use the manufacturer’s taps for that voltage.
Why can voltage drop be lower than this 95 m far-end estimate?
Earlier taps draw current before the end of the route. Placing all current at the far end models the greatest full-length loop drop for that combined load.