2 kHz Linkwitz–Riley LR2 Crossover and Tweeter Polarity
A two-way design uses two 8 Ω resistive prototype loads and a second-order LR handoff. Compare this with fourth order by changing the order selector.
- Crossover frequency
- 2,000 Hz
- Filter alignment
- Linkwitz–Riley
- Filter order
- 2nd · 12 dB/oct
- Woofer load
- 8 Ω
- Tweeter load
- 8 Ω
- Tweeter attenuation
- 0 dB
- Voice-coil DC resistance (Re)
- 6.2 Ω
- Voice-coil inductance (Le)
- 0.7 mH
Results
- Woofer series L1
- 1.273mH
- Tweeter series C1
- 4.974µF
- Asymptotic slope per branch
- 12dB/oct
- Branch level at crossover, before pad
- -6.02dB
- L-pad series resistor
- 0Ω
- L-pad shunt resistor
- Open (bypass)
- Zobel resistor
- 6.2Ω
- Zobel capacitor
- 18.21µF
The two branches share the amplifier input and return. Fit the pad and Zobel at their respective driver terminals.
The vertical line marks crossover frequency. The tweeter trace includes the entered L-pad attenuation.
Crossover components
| Branch | Part | Connection | Value |
|---|---|---|---|
| Woofer | L1 | Series | 1.2732 mH |
| Woofer | C1 | Shunt | 4.9736 µF |
| Tweeter | C1 | Series | 4.9736 µF |
| Tweeter | L1 | Shunt | 1.2732 mH |
Impedance and level correction
| Network | Part | Value |
|---|---|---|
| Tweeter L-pad | Series resistor | 0 Ω |
| Tweeter L-pad | Shunt resistor | Open |
| Woofer Zobel | Series resistor | 6.2 Ω |
| Woofer Zobel | Series capacitor | 18.2102 µF |
Worked calculation
Convert the crossover frequency to angular frequency
ω = 2π × 2,000 = 12,566.37 rad/s
Scale the normalized ladder
Linkwitz–Riley 2 → g = [2, 0.5]. Woofer L₁ = g₁ × 8 ÷ ω = 1.2732 mH. Tweeter C₁ = 1 ÷ (g₁ × 8 × ω) = 4.9736 µF
Read the electrical levels at the crossing
Woofer = -6.021 dB. Tweeter after 0 dB pad = -6.021 dB
What the example shows
At 2 kHz both electrical branches are about −6 dB. The ideal LR2 branches have opposite phase, so reverse one driver to sum on the design axis under coincident-driver assumptions.
Model assumptions
- The ideal voltage source feeds two ladders terminated in the entered resistances. The response is electrical, and the tweeter curve includes the L-pad level shift.
- Place the L-pad after the high-pass ladder, with its shunt resistor across the tweeter. Connect the series R–C Zobel across the woofer. Use measured driver impedance and acoustic response to refine a real build.
- In an ideal coincident LR2 system, reverse one driver’s polarity to align the branches. Confirm polarity and offsets with a measurement.
Common questions
Does the sign of the LR2 tweeter connection affect its magnitude curve?
Reversing polarity changes the phase by 180 degrees and leaves the individual magnitude unchanged. The combined acoustic response can change substantially.
Which 2 kHz LR2 component is the first inductor for the woofer?
The series inductor is about 1.273 mH for an 8 Ω load. The shunt capacitor follows it at the woofer node.