Worked example · Engine

350 WHP Turbo Six with Custom BSFC at 75% Duty

Size six gasoline injectors for 350 WHP using 0.64 custom BSFC, 18% drivetrain loss and 75% duty.

Setup

Power and fuel
hp
%
Assumes one primary injector per cylinder.
Rating and rail differential
lb/(hp·h)
Blank uses the fuel and induction preset.
%
psi
psi
Rail pressure minus intake manifold pressure.
View results

Results

Runs in your browser
Minimum catalog rating
60.7 lb/hr
616 cc/min at 43.5 psi
Required flow at the rail
60.7 lb/hr
616 cc/min per injector
Equivalent crank power
426.8 hp
318.3 kW
Pressure flow multiplier
1 ×
Operating flow ÷ catalog flow
Injector flow at differential pressure
Minimum injector flow by pressure differentialThe line models square-root pressure scaling for the smallest injector that meets the estimated operating demand. 001419283841565575FLOW / LB PER HOURpsi differentialSupplier ratingOperating
Fuel assumptions and comparison
MeasurementResult
BSFC used0.64 lb/(hp·h)
Total engine fuel flow273.17 lb/hr
Conversion density0.745 g/cc
E85 vs gasoline, stoichiometric mass at equal air+47 %
E85 vs gasoline, stoichiometric volume at equal air+40.4 %

Spec sheet

Worked math for the starting setup

  1. Back out the loss

    350 ÷ 0.82 = 426.83 crank hp at the entered assumed drivetrain efficiency.

  2. Use the measured BSFC assumption

    426.83 × 0.64 ÷ (6 × 0.75) ≈ 60.7 lb/hr per injector.

Custom BSFC takes precedence over induction presets. Check that the measured BSFC was reported on a crank-power basis.

See formulas and assumptions for injector sizing & e85

Common questions

Is the gas turbo preset still used when I type 0.64 BSFC for the 350 WHP six?

The 0.64 custom input replaces the default 0.60 gasoline turbo assumption.

How would changing from 75% to 80% duty affect this six-cylinder injector demand?

At the same power and BSFC the required static flow becomes 75 ÷ 80 of the original, a 6.25% reduction.