A cold-weather pellet cook with a reserve
See what a 20°F day does to a 10-hour pellet cook at 275°F.
The setup
The forecast increases the fuel rate for the larger gap between pit and outdoor temperatures. Wind and the cooker’s insulation can make your measured rate different.
Results
Check the highlighted inputs to update the result.
Fuel for cook and reserve
16.84 lb
Pellets · $11.79 at your unit price
About 1.16 lb remains after covering the forecast and reserve.
| Result | Amount |
|---|---|
| Steady burn rate | 1.31 lb/h |
| Startup use | 0.35 lb |
| Cook fuel | 13.48 lb |
| Reserve | 3.37 lb |
| Estimated hours on hand | 13.4 h |
| Energy in cook fuel | 110,495 BTU |
| Estimated cost | $11.79 |
Inputs
- Cooker
- Pellet grill
- Cook duration
- 10 h
- Pit temperature
- 275 °F
- Outdoor temperature
- 20 °F
- Fuel on hand
- 18 lb
- Fuel price
- 0.7 $/lb
- Extra fuel reserve
- 25 %
- Measured reference burn rate
- 0 lb/h
Try a change
Set outdoors to 70°F and compare with the cold-day estimate. Hold the duration and pit temperature steady.
How the calculation works
Fuel to have on hand = (startup + hourly burn × hours) × (1 + reserve fraction)
An offset uses wood splits, a kamado or kettle uses lump, a pellet grill uses pellets, and a propane smoker uses propane. The burn-rate adjustment scales a reference rate by 0.4 plus 0.6 times the pit-to-outdoor temperature difference divided by 180°F. Energy is estimated from the fuel burned, excluding unused reserve.
- Use an observed steady burn measured near 250°F pit and 70°F outdoors when you have one. Wind, moisture, insulation and cooker size can change fuel use.
- The energy values are approximate BTU content of fuel, before cooker heat losses. For propane, enter the cylinder’s net fuel weight after subtracting its tare weight.
References
Questions and answers
Which change costs more pellets here, colder air or an extra hour?
Try changing one input at a time. Colder air changes every hour’s rate, while another hour extends the cook at the current rate.
Does this cold-day model account for gusts?
Use the reserve for uncertainty and compare with your cooker’s own logs. The estimate uses air temperature and a reference burn rate.