Worked example

200 W FTP Sweet Spot and a 90-Minute TSS Estimate

Calculate load for a 90-minute session at 176 W Normalized Power on a 200 W FTP, with separate power and heart-rate bands.

Calculator

Change any input to update the results.

Setup inputs

Thresholds and session
W
bpm
kg
W
Use the session’s NP. You can enter expected NP for planning.
min
Fuel plan
g/h
mL/h

Results

FTP to weight
3.03W/kg
Intensity Factor
0.88
Training load
116.2TSS
Carbohydrate total
75g
Seven FTP power zones
Power zones and Normalized Power markerThe horizontal scale shows the seven FTP zones and the location of entered Normalized Power.FTP 200 WNP 176 W · Z3Z1Z2Z3Z4Z5Z6Z71101501802102403000Power (W)
Zone widths scale with the FTP cutoffs. The marker shows the entered Normalized Power. The open-ended sprint zone extends beyond the last tick.
Detailed results
Power and cycling heart-rate bands
Power zoneNamePower (W)HR zoneHeart rate (bpm)
Z1Active recovery0–110Z10–132
Z2Endurance111–150Z2133–147
Z3Tempo151–180Z3148–154
Z4Threshold181–210Z4155–163
Z5VO₂ max211–240Z5a164–168
Z6Anaerobic241–300Z5b169–175
Z7Neuromuscular301 and upZ5c176 and up
Ride supplies
QuantityValueUnit
Carbohydrates75g
Fluid0.68L

Build sheet

Worked calculation

Plan the work-interval watts separately from whole-session Normalized Power. Warm-up and recovery change the session’s intensity even when the work sets repeatedly hit the same target.

  1. Convert FTP and find the endurance band

    200 W ÷ 66 kg = 3.03 W/kg · Z2 111–150 W

  2. Set the cycling heart-rate bands

    0.81 × 164 bpm, rounded up, gives 133 bpm at the start of Z2

  3. Calculate session intensity and load

    IF = 176 ÷ 200 ≈ 0.880 · 100 × (90 ÷ 60) × IF² ≈ 116.2 TSS

  4. Total the chosen supplies

    50 g/h and 450 mL/h for 90 min → 75.0 g and 0.68 L

How it works

The first six power zones use upper cut points of 55%, 75%, 90%, 105%, 120% and 150% of FTP. The sprint band is charted above 150% as a display convention. Neuromuscular work is best measured by short maximal efforts and recovery quality.

Cycling heart-rate bands use LTHR lower cut points of 81%, 90%, 94%, 100%, 103% and 107%. For whole-unit displays, a power band begins 1 W after the previous band ends, and each heart-rate threshold is rounded up to the next whole bpm.

Intensity Factor is Normalized Power ÷ FTP. TSS is 100 × hours × IF². Fuel and fluid totals multiply your own hourly targets by duration. Adjust those targets for conditions and what you can tolerate.

Common questions

What IF results from 176 W Normalized Power and 200 W FTP?

176 ÷ 200 gives an intensity factor of 0.88.

Does the sweet-spot target always sit in one Coggan zone?

Sweet-spot ranges vary by coach and can straddle the high end of tempo and lower threshold. Use the workout’s prescribed watts.