Bucket fill f and pitch p describe one row of buckets. The rate assumes steady full-width feeding at the specified bucket loading. Belt or chain pitch speed and head diameter must use consistent units.
Centrifugal reference
N꜀ = (60/2π)√(g/R) ≈ 29.90/√Rₘ ≈ 42.29/√Dₘ
R is half of the head pulley diameter D. The metric coefficients use metres for Rₘ and Dₘ. The check compares pulley acceleration with gravity. Centrifugal buckets discharge by throwing material, while slower continuous elevators rely on gravity and bucket shape. Use the effective radius of the real bucket lip to check trajectory and discharge.
Hdig is an editable equivalent material lift for digging resistance. Specify empty running power separately. Calculate startup, chain or belt tensions and backstop requirements with the manufacturer.
Speed is consistent with the selected discharge mode.
Inputs
Discharge type
Centrifugal
Bucket volume
0.45 ft³
Bucket fill
75%
Bucket pitch
14 in
Belt or chain speed
390 FPM
Vertical lift
80 ft
Bulk density
75 lb/ft³
Head pulley diameter
24 in
Equivalent digging head
6 ft
Empty elevator power
0.75 HP
Drive efficiency
90%
Calculated values
Mass throughput
253.848TPH
Headshaft speed
62.07RPM
Critical centrifugal speed
54.166RPM
Motor power
25.335HP
Volume throughput
6,769.286CFH
Material lift power
20.513HP
Digging power
1.538HP
Headshaft power
22.801HP
Headshaft torque
23,152.253lb-in
Head speed / critical
114.594%
Industrial machinery and mobile equipment can cause fatal injuries. Use these estimates for preliminary sizing. Follow the MSHA or OSHA requirements that apply at your site. Guard moving parts and nip points, and use site lockout/tagout and hazardous-energy isolation procedures before service. Have qualified personnel verify equipment selection and operating limits.