Worked example · Crusher & Bond Energy

Hard basalt reduction stage

A high-work-index basalt feed is reduced to sub-inch product in a quarry circuit.

Live results

F80 to P80 reduction and Bond energy curve

Edit inputs
F80 to P80 reduction and Bond energy curve Four live readings and a schematic of the selected material-handling configuration. Full values follow the diagram. REDUCTION8BOND ENERGY0.97kWh/short tonNET POWER338.07HPMOTOR POWER388.59HP CRUSHING SECTIONBOND ENERGY CURVEFeed F805.6 inProduct P800.7 inFeed sizeFiner product Reduction in 80% passing size87.5%Use a tested work index and circuit corrections for design.

Use a tested work index and circuit corrections for design.

All calculated values
Reduction ratio F80/P80
8
Bond specific energy
0.97kWh/short ton
Net comminution power
338.07HP
Motor power
388.586HP
Decrease in P80 size
87.5%

Inputs

Unit system
Operating inputs
in
in
kWh/short ton
TPH
Drive & model factors
%

Worked solution

Starting case in US units

  1. Divide feed F80 of 5.6 in by product P80 of 0.7 in to obtain a 8:1 reduction ratio.
  2. Convert both sizes to µm and use Wi = 20 kWh/short ton in the Bond equation. The energy estimate is 0.97 kWh/short ton.
  3. At 260 TPH feed, estimated net power is 338.07 HP. Applying drive efficiency of 87% gives a 388.59 HP motor estimate.

Try it. Compare basalt with the limestone work-index preset at equal F80, P80 and feed. Specific energy scales linearly with Wi.

More worked examples

Open a different starting case

Equations and assumptions

Use 80% passing sizes

RR = F₈₀ / P₈₀

F80 and P80 are the sizes through which 80% of the feed and product mass pass. Reduction ratio uses equal size units. The Bond equation converts both to micrometres.

Bond Third Theory

W = 10 · Wᵢ · (1/√P₈₀ − 1/√F₈₀)
Pnet = W · Qₘ   |   Pmotor = Pnet/η

Bond originally used kWh per short ton. A short ton is exactly 0.90718474 metric tonnes. The calculator converts W and Wi together, and multiplies by throughput on the matching tonnage basis. Display presets are illustrative kWh/short ton values. Actual ore test results, crusher class and circuit correction factors determine design power.

References