Eastern White Pine Door Panel in a Heated Room

A 300 mm pine panel in a painted cupboard drops to 5% wood moisture in winter and climbs to 10% after the heating season.

The low endpoint is outside the coefficient’s calibration range. Treat the result as an estimate and compare it with observed movement on a sample offcut.

Measurements

Board and growth rings
mm
mm
Added to predicted expansion across the full panel.
Seasonal conditions
%
%
View drawing

Live drawing

Edit measurements
Winter and summer width and moisture comparison PANEL WIDTH AT EQUILIBRIUMWinter · 300 mmSummer · 303.18 mm5% winter EMC10% summer EMCSeasonal travel 3.18 mmTotal gap 4.68 mm
The bars compare physical width. The two marks below show the seasonal equilibrium moisture contents.
Winter EMC
5%
Summer EMC
10%
Width change
3.18 mm
Gap at winter width
4.68 mm

One or both EMC values fall outside 6–14%. The result extrapolates the published coefficient.

Plan details

Summer width
303.18 mm
Seasonal travel
3.18 mm
Gap per edge if centered
2.34 mm
Radial coefficient
0.00071
Tangential coefficient
0.00212
Applied coefficient per EMC point
0.00212

Seasonal dimensions

ConditionEMCWidth
Winter5%300 mm
Summer10%303.18 mm

How the calculation works

  1. Measure across the grain

    Enter the panel width in its winter condition. Choose plainsawn for tangential movement and quartersawn for radial movement.

  2. Use the room’s seasonal extremes

    Enter indoor relative humidity at a shared temperature, or enter measured wood-moisture endpoints directly.

  3. Leave room in the joint

    The gap at the winter width is predicted expansion plus your fit allowance. Divide the gap between both sides when the panel is fixed on center.

Formula

Width change = starting width × species coefficient × (summer EMC − winter EMC). RH mode uses the Hailwood–Horrobin relationship.

The USDA dimensional-change coefficients are intended for wood at 6–14% moisture content. Real movement varies with the board, grain orientation, exposure and time at equilibrium.

Frequently asked questions

Why does the pine cupboard panel show an EMC range warning?

The published dimensional-change coefficient is intended for 6% to 14% moisture. The 5% input falls below that range.

Can the pine panel still move once it is painted?

Paint slows moisture exchange. Given enough time, seasonal humidity can still change the panel’s width.