45° Spring Crown on a 135° Outside Bay Return

A shallow pop-out meets a 135° outside return. A 100 mm diagonal profile has a 45° spring from the wall.

Check the estimated wall and ceiling coverage before marking the ends. Be sure to identify the keeper for nested cuts separately from flat cuts.

Measurements

Molding and corner
mm
Straight-line distance between the ceiling and wall contact edges.
View drawing

Live drawing

Edit measurements
Wall corner and saw settings WALL PLANSAW HEAD AND TABLE135° outsideTilt 15.7°Miter 16.32°Ceiling projection 70.71 mmWall drop 70.71 mm
Wall plan and saw settings for the left installed piece. The right piece mirrors both saw angles.
Flat miter
16.32°
Flat bevel
15.7°
Nested miter
22.5°
Nested bevel
0°

Plan details

Spring from wall
45°
Wall angle
135°
Ceiling projection
70.71 mm
Wall drop
70.71 mm

Saw settings by installed side

Installed sideFlat miterFlat bevelFlat keeperNested miterNested keeper
Left16.32° left15.7° rightLeft22.5° leftRight
Right16.32° right15.7° leftRight22.5° rightLeft

How the calculation works

  1. Measure the spring and corner

    Read spring from the wall to the broad back of the molding. For an outside corner enter the smaller angle between wall faces.

  2. Choose flat or nested

    For flat cuts, put the broad back down and the ceiling edge against the fence. For nested cuts, hold the wall edge against the fence and the ceiling edge on the table.

  3. Mark the keeper

    The table follows the DeWalt DWS780 convention for the installed left and right pieces. Compare its orientation with your saw manual and verify the fit in scrap.

Formula

With spring S and wall angle C, flat miter = atan(sin S ÷ tan(C/2)), bevel = asin(cos S × cos(C/2)), and nested miter = 90° − C/2.

The settings assume equal profiles meeting on plumb walls under a level ceiling. The diagram shows angular geometry. The physical fence and saw limits vary by machine.

Frequently asked questions

How far does this 100 mm 45° crown project onto the ceiling?

The projected diagonal component is about 70.71 mm.

Why is the nested keeper on the opposite side of the blade in this example?

The nested setup turns the molding over so the wall edge sits at the fence. The table follows that orientation.