Narrow Face-Frame Floor Cabinet with Toe-Kick
A 15-inch floor cabinet gets a face frame, a 4-inch toe-kick and a single overlay door. The 3/4-inch carcass uses a captive back.
Leave depth for the toe rail behind the notch. Check hinge overlay against the stile width and use the door dimension after confirming the frame is square.
Measurements
Live drawing
Edit measurements- Cut pieces
- 12
- Edge banding
- 96.4213 in
- Clear opening width
- 12 in
- Clear opening height
- 27.5 in
Plan inputs
Cabinet style Face frame · Outside width 15 in · Overall height 34.5 in · Box depth including back 23 in · Carcass thickness 0.75 in · Toe-kick height 4 in · Toe-kick notch depth 3 in · Face-frame stile width 1.5 in · Face-frame rail width 1.5 in · Face-frame thickness 0.75 in · Back construction Captured in four grooves · Back thickness 0.236220472 in · Back groove depth 0.236220472 in · Back inset from rear 0.472440945 in · Adjustable shelves 1 · Shelf side gap per edge 0.039370079 in · Shelf front setback 0.75 in · Door count Single door · Door fit Overlay · Overlay per perimeter edge 0.5 in · Door stock thickness 0.748031496 in
Plan details
- Inside carcass width
- 13.5 in
- Clear shelf depth before setback
- 22.2913 in
- Total banding
- 8.035 ft
- Pin diameter
- 0.1969 in
- Front pin row from carcass front
- 1.4567 in
- Rear pin row from carcass front
- 20.8346 in
- Side notch height
- 4 in
- Side notch depth
- 3 in
- Each door width
- 13 in
- Door height
- 28.5 in
- Side perimeter reveal
- 1 in
- Top / bottom perimeter reveal
- 1 in
Cabinet panel cut list
| Part | Qty | Length | Width | Thickness | Band each |
|---|---|---|---|---|---|
| Side with toe notch | 2 | 34.5 in | 23 in | 0.75 in | 0 in |
| Top / bottom | 2 | 13.5 in | 23 in | 0.75 in | 0 in |
| Captured back | 1 | 29.4724 in | 13.9724 in | 0.2362 in | 0 in |
| Recessed toe rail | 1 | 13.5 in | 4 in | 0.75 in | 0 in |
| Adjustable shelf | 1 | 13.4213 in | 21.5413 in | 0.75 in | 13.4213 in |
| Face-frame stile | 2 | 30.5 in | 1.5 in | 0.75 in | 0 in |
| Face-frame rail | 2 | 12 in | 1.5 in | 0.75 in | 0 in |
| Slab door | 1 | 28.5 in | 13 in | 0.748 in | 83 in |
32 mm drilling stations on each side
| Station | Y from bottom of side | Front X | Rear X |
|---|---|---|---|
| 1 | 6.0217 in | 1.4567 in | 20.8346 in |
| 2 | 7.2815 in | 1.4567 in | 20.8346 in |
| 3 | 8.5413 in | 1.4567 in | 20.8346 in |
| 4 | 9.8012 in | 1.4567 in | 20.8346 in |
| 5 | 11.061 in | 1.4567 in | 20.8346 in |
| 6 | 12.3209 in | 1.4567 in | 20.8346 in |
| 7 | 13.5807 in | 1.4567 in | 20.8346 in |
| 8 | 14.8406 in | 1.4567 in | 20.8346 in |
| 9 | 16.1004 in | 1.4567 in | 20.8346 in |
| 10 | 17.3602 in | 1.4567 in | 20.8346 in |
| 11 | 18.6201 in | 1.4567 in | 20.8346 in |
| 12 | 19.8799 in | 1.4567 in | 20.8346 in |
| 13 | 21.1398 in | 1.4567 in | 20.8346 in |
| 14 | 22.3996 in | 1.4567 in | 20.8346 in |
| 15 | 23.6594 in | 1.4567 in | 20.8346 in |
| 16 | 24.9193 in | 1.4567 in | 20.8346 in |
| 17 | 26.1791 in | 1.4567 in | 20.8346 in |
| 18 | 27.439 in | 1.4567 in | 20.8346 in |
| 19 | 28.6988 in | 1.4567 in | 20.8346 in |
| 20 | 29.9587 in | 1.4567 in | 20.8346 in |
| 21 | 31.2185 in | 1.4567 in | 20.8346 in |
| 22 | 32.4783 in | 1.4567 in | 20.8346 in |
How the calculation works
Set the finished box envelope
Overall height includes the toe space. Depth includes the back and excludes the face frame and doors. The full-height sides carry the top and bottom.
Choose back and door construction
An applied back covers the rear above the toe. A captured back fits into four grooves. Overlay extends from the opening and inset reveal reduces it.
Lay out the pins
Use 5 mm holes at 32 mm pitch. X starts at the carcass front edge. Y starts at the bottom of the side, including its toe extension.
Formula
Top and bottom width = outside width − 2 × carcass thickness. Captured back width = that inside width + 2 × groove depth.
Banding counts the visible frameless front edges, shelf fronts and slab-door perimeters. Pin rows are 37 mm from the front and inside back plane. Fastener and hinge locations depend on the selected hardware.
Frequently asked questions
What does a half-inch overlay do to the narrow cabinet door width?
It adds one inch across the pair of edges, taking a 12-inch opening to a 13-inch door.
Why are the floor cabinet frame stiles shorter than its side panels?
The frame starts above the toe-kick. The side panels extend down to the floor.