Tall Pantry with 32 mm Shelf Pin Rows

A 500 mm tall-format pantry case stands 2,150 mm high with six adjustable shelves and a recessed 8 mm captured back.

Mark one story stick for the face reference of both sides. Keep the rear pin row clear of the captured back and its groove.

Measurements

Carcass
mm
mm
Include the toe-kick height.
mm
Measure from the front of the carcass to the rear. Exclude the frame and doors.
mm
mm
mm
Back and shelves
mm
mm
mm
mm
mm
Slab doors
mm
mm
View drawing

Live drawing

Edit measurements
Cabinet front elevation and side pin layout FRONT ELEVATIONSIDE PANEL500 mm585 mm
The front shows the door envelope and sample shelf positions. The side view shows the back, toe notch and drilling lines.
Cut pieces
13
Edge banding
12,790 mm
Clear opening width
464 mm
Clear opening height
1,994 mm

Plan details

Inside carcass width
464 mm
Clear shelf depth before setback
561 mm
Total banding
41.962 ft
Pin diameter
5 mm
Front pin row from carcass front
37 mm
Rear pin row from carcass front
524 mm
Side notch height
120 mm
Side notch depth
70 mm
Each door width
494 mm
Door height
2,024 mm
Side perimeter reveal
3 mm
Top / bottom perimeter reveal
3 mm

Cabinet panel cut list

PartQtyLengthWidthThicknessBand each
Side with toe notch22,150 mm585 mm18 mm2,030 mm
Top / bottom2464 mm585 mm18 mm464 mm
Captured back12,006 mm476 mm8 mm0 mm
Recessed toe rail1464 mm120 mm18 mm0 mm
Adjustable shelf6461 mm540 mm18 mm461 mm
Slab door12,024 mm494 mm19 mm5,036 mm

32 mm drilling stations on each side

StationY from bottom of sideFront XRear X
1175 mm37 mm524 mm
2207 mm37 mm524 mm
3239 mm37 mm524 mm
4271 mm37 mm524 mm
5303 mm37 mm524 mm
6335 mm37 mm524 mm
7367 mm37 mm524 mm
8399 mm37 mm524 mm
9431 mm37 mm524 mm
10463 mm37 mm524 mm
11495 mm37 mm524 mm
12527 mm37 mm524 mm
13559 mm37 mm524 mm
14591 mm37 mm524 mm
15623 mm37 mm524 mm
16655 mm37 mm524 mm
17687 mm37 mm524 mm
18719 mm37 mm524 mm
19751 mm37 mm524 mm
20783 mm37 mm524 mm
21815 mm37 mm524 mm
22847 mm37 mm524 mm
23879 mm37 mm524 mm
24911 mm37 mm524 mm
25943 mm37 mm524 mm
26975 mm37 mm524 mm
271,007 mm37 mm524 mm
281,039 mm37 mm524 mm
291,071 mm37 mm524 mm
301,103 mm37 mm524 mm
311,135 mm37 mm524 mm
321,167 mm37 mm524 mm
331,199 mm37 mm524 mm
341,231 mm37 mm524 mm
351,263 mm37 mm524 mm
361,295 mm37 mm524 mm
371,327 mm37 mm524 mm
381,359 mm37 mm524 mm
391,391 mm37 mm524 mm
401,423 mm37 mm524 mm
411,455 mm37 mm524 mm
421,487 mm37 mm524 mm
431,519 mm37 mm524 mm
441,551 mm37 mm524 mm
451,583 mm37 mm524 mm
461,615 mm37 mm524 mm
471,647 mm37 mm524 mm
481,679 mm37 mm524 mm
491,711 mm37 mm524 mm
501,743 mm37 mm524 mm
511,775 mm37 mm524 mm
521,807 mm37 mm524 mm
531,839 mm37 mm524 mm
541,871 mm37 mm524 mm
551,903 mm37 mm524 mm
561,935 mm37 mm524 mm
571,967 mm37 mm524 mm
581,999 mm37 mm524 mm
592,031 mm37 mm524 mm
602,063 mm37 mm524 mm
612,095 mm37 mm524 mm

How the calculation works

  1. Set the finished box envelope

    Overall height includes the toe space. Depth includes the back and excludes the face frame and doors. The full-height sides carry the top and bottom.

  2. Choose back and door construction

    An applied back covers the rear above the toe. A captured back fits into four grooves. Overlay extends from the opening and inset reveal reduces it.

  3. Lay out the pins

    Use 5 mm holes at 32 mm pitch. X starts at the carcass front edge. Y starts at the bottom of the side, including its toe extension.

Formula

Top and bottom width = outside width − 2 × carcass thickness. Captured back width = that inside width + 2 × groove depth.

Banding counts the visible frameless front edges, shelf fronts and slab-door perimeters. Pin rows are 37 mm from the front and inside back plane. Fastener and hinge locations depend on the selected hardware.

Frequently asked questions

Where does the pantry rear pin line land with a 24 mm back assembly allowance?

Clear cavity depth is 561 mm. Measure 524 mm from the front edge, which is 37 mm clear of the inside back plane.

Can I shorten the pantry pin series around a fixed shelf?

Use the provided coordinates as a common grid and omit stations blocked by the fixed part.