Quartersawn Red Oak Floating Cabinet Panel

A 450 mm northern red oak door panel is quartersawn. The wood cycles between 7% and 12% moisture inside the kitchen.

Use the radial result to plan clearance in the grooves. Confirm the growth ring orientation on the panel edges, especially on mixed stock.

Measurements

Board and growth rings
mm
mm
Added to predicted expansion across the full panel.
Seasonal conditions
%
%
View drawing

Live drawing

Edit measurements
Winter and summer width and moisture comparison PANEL WIDTH AT EQUILIBRIUMWinter · 450 mmSummer · 453.08 mm7% winter EMC12% summer EMCSeasonal travel 3.08 mmTotal gap 4.08 mm
The bars compare physical width. The two marks below show the seasonal equilibrium moisture contents.
Winter EMC
7%
Summer EMC
12%
Width change
3.08 mm
Gap at winter width
4.08 mm

Plan details

Summer width
453.08 mm
Seasonal travel
3.08 mm
Gap per edge if centered
2.04 mm
Radial coefficient
0.00137
Tangential coefficient
0.00304
Applied coefficient per EMC point
0.00137

Seasonal dimensions

ConditionEMCWidth
Winter7%450 mm
Summer12%453.08 mm

How the calculation works

  1. Measure across the grain

    Enter the panel width in its winter condition. Choose plainsawn for tangential movement and quartersawn for radial movement.

  2. Use the room’s seasonal extremes

    Enter indoor relative humidity at a shared temperature, or enter measured wood-moisture endpoints directly.

  3. Leave room in the joint

    The gap at the winter width is predicted expansion plus your fit allowance. Divide the gap between both sides when the panel is fixed on center.

Formula

Width change = starting width × species coefficient × (summer EMC − winter EMC). RH mode uses the Hailwood–Horrobin relationship.

The USDA dimensional-change coefficients are intended for wood at 6–14% moisture content. Real movement varies with the board, grain orientation, exposure and time at equilibrium.

Frequently asked questions

Which coefficient applies to the quartersawn northern red oak panel?

Its width follows the radial direction, so the calculator uses 0.00137 per moisture point.

How much total slot clearance does the red oak panel need at winter width?

About 4.08 mm, including the extra 1 mm of fitting clearance.