Load transfer

Composite bolted joint

Compare bearing, net-tension and shear-out margins for a loaded composite joint.

View live results

Inputs

Bolt group
N
Critical-hole geometry
mm
mm
mm
mm
Laminate allowables
MPa
MPa
MPa

Live results

SI
Bolt force
3,780 N
Bearing
248.03 MPa
Net tension
72.748 MPa
Min. margin
0.9554
PassGeometry screen met · Bearing
Critical-hole load path
Plan view of a loaded hole, bearing contact, net section and shear-out planes wew/d 4.41e/d 3.15d
  • Bearing contact
  • Net section
  • Shear-out planes
Limit utilization51.141%
0%100% limit

Nominal stress and margin

ModeStressMargin
Bearing248.031 MPa0.955397
Net tension72.7483 MPa2.98635
Shear-out39.375 MPa1.84444

Geometry and net-plane comparison

Width ratio w/d
4.40945
Edge ratio e/d
3.14961
Width margin w − 4d
2.6 mm
Edge margin e − 3d
0.95 mm
Net ligament e − d/2
16.825 mm
Net-plane shear
46.8053 MPa

Model and assumptions

Pbolt = P·factor/n · σbr = Pbolt/(dt) · σnt = Pbolt/[(w − d)t] · τso = Pbolt/(2et).

Treat P as the total group load. A factor of 1 gives equal sharing, and a larger factor raises the demand on the critical bolt. The strip is checked at a single hole with effective width w.

The screening geometry uses w/d ≥ 4 and e/d ≥ 3 as local design heuristics in the context of ASTM D5961 and MIL-HDBK-17. Test geometries and allowable data depend on the specific procedure and layup.

Margin is allowable divided by nominal stress, minus one. The comparison using e − d/2 shows a different net-plane stress. Use an allowable calibrated to that same stress convention before assigning a net-plane margin.

Scope. Preliminary in-plane static screening. Fastener strength, contact, bearing–bypass interaction, wedge splitting, fatigue and progressive damage need separate checks.

See calculation methods and references