Worked example

Thick carbon root preform

Size a batch for a thick preform with a large feedline and flow-media allowance.

Use both mixed mass and cured areal weight to distinguish process consumption from material left in the laminate.

View live results

Inputs

Layup
g/m²
m²
%
g/cm³
Resin system
g/cm³
%

Live results

SI
Cured stack
7.4713 mm
Mixed batch
1,865.2 g
Resin mass
1,457.2 g
Hardener mass
408.01 g
Cured stack and batch mass
Cured layup thickness and dry fiber, resin and hardener mass budget 26 plies7.47 mmFiber2,890Resin1,460Hardener408g
  • Dry fiber
  • Resin
  • Hardener
Fiber weight share of cured part67.625%
0%100% of cured mass

Layup and batch balance

Dry fiber mass
2,886 g
In-part matrix mass
1,381.63 g
Additional mix for waste
483.571 g
Cured ply thickness
0.287356 mm
Cured areal weight
11,534.1 g/m²
Fiber volume fraction
58 %
Fiber weight fraction
67.6253 %

Model and assumptions

Mf = FAW·A·N · tply = FAW/(1000ρfVf) in mm · Mbatch = Mmatrix(1 + waste).

Use dry fiber areal weight for a single ply and the actual developed part area. The target fiber fraction is a cured-part value. Mixed matrix mass uses the combined resin-system density.

Waste is an additional percentage of the mixed matrix mass needed in the part. The batch split uses weight parts and applies the same ratio to resin retained in the part and waste.

Cured ply thickness follows fiber volume conservation. Press pressure, resin bleed, cure shrinkage and voids affect practical thickness.

Scope. Uniform ply coverage, no void volume and mass-based resin manufacturer ratios. Add process waste from your own feedline, peel ply or bleeder records.

See calculation methods and references