Worked example

Asymmetric instrument panel

Compare top and bottom stress when an instrument panel has thinner compression-facing material.

The neutral axis shifts toward the thicker bottom face. Compression at the outer top fiber can govern despite identical facing moduli.

View live results

Inputs

Beam and load
N
mm
mm
Facesheets
mm
mm
GPa
MPa
Core
mm
MPa
MPa
MPa

Live results

SI
Deflection
3.1482 mm
Core shear
0.192 MPa
Wrinkle limit
305.12 MPa
Reserve factor
3.5645
PassGoverning mode · Face wrinkling
Sandwich beam section
Beam load positions, sandwich cross section and deflection composition t₁t₂cdBend 68.4%Shear 31.6%
  • Load / bending
  • Shear deflection
  • Core
Limit utilization28.054%
0%100% limit

Beam response

Bending deflection
2.15229 mm
Shear deflection
0.995944 mm
Peak moment
66,150 N·mm
Peak shear force
315 N

Cross-section stiffness

Centroid spacing d
14.915 mm
Overall thickness
15.83 mm
Separation D
4.09613e+6 N·mm
Local face D
11,140.9 N·mm
Per-width D
4.10727e+6 N·mm
Strip rigidity EI
4.518e+8 N·mm²
Shear stiffness U
66,419.4 N

Mode checks

ModePeak stressReserve
Face compression85.5981 MPa4.2057
Face tension34.9243 MPa10.308
Core shear0.191997 MPa7.03136
Face wrinkling85.5981 MPa3.56452

Model and assumptions

EI = bD · U = Gc·b·d²/c · δtotal = δbend + δshear · σwr = 0.5∛(EfEcGc).

The beam is simply supported. For three-point loading P acts at midspan. Four-point loading splits total P equally at the quarter points. The uniformly distributed load has intensity P/L.

The neutral axis follows the two facesheet areas. Separation and local facesheet bending both contribute to D. The core carries shear through U, with nominal core stress V/(bd). Peak facesheet stresses are taken at the outer fibers.

The 0.5 cube-root expression is the Hoff–Mautner type wrinkling screen for a homogenized core. Plantema-type theory addresses the same mode with different coefficients and assumptions. Cell dimpling requires cell-size data and a separate check.

Scope. Small-deflection beam model with equal facing modulus, independent facing thicknesses and a uniform core. Local load introduction, bond failure and dimpling require additional checks.

See calculation methods and references