DistillColumnLab
Menu

Worked example · Reaction engineering

Low-conversion CSTR penalty

Compare ideal reactor volumes, space time and equal-tank conversion for zero-, first- or second-order kinetics.

For a second-order polishing duty, compare reactor volumes at just 3% conversion.

CSTR volume
0.3673 m³
PFR volume
0.3563 m³
CSTR / PFR
1.031
Cascade X
2.957 %

Levenspiel volume comparison

Live schematic
Levenspiel plot of PFR area under the rate curve and the CSTR rectangle00.00670.0130.020.0270.03403.46.91014Fₐ₀ / (−rₐ) · m³CONVERSION XPFR areaCSTR rectangleCascade check
Cascade close to target

The conversion check holds total cascade volume at the PFR volume. Use the separate cascade size to meet the target.

PFR-sized cascade conversion vs target2.96 %
Near target 2.98 % Target 3 %

Worked solution

  1. Evaluate the rate at temperature

    The Arrhenius correction gives k = 0.5 m³/(kmol·h). At X = 3 %, CA = 1.212 kmol/m³.

  2. Compare the Levenspiel areas

    The outlet-rate rectangle gives 0.3673 m³. Integrating through the concentration change gives 0.3563 m³. The single-tank penalty is 1.031 times.

  3. Check the cascade

    2 equal tanks at PFR total volume reach 2.957 %. At the target, the cascade requires 0.3618 m³ total.

At low conversion the rate changes little along the reactor, so the volume penalty is small. The derivation uses SI units.

Calculation details
Operating rate constant0.5 m³/(kmol·h)
Total cascade volume at target0.3618 m³
Volume per equal tank0.1809 m³
CSTR space time0.05101 h
PFR space time0.04948 h
Cascade space time at target0.05024 h
Outlet concentration CA1.212 kmol/m³
PFR-sized cascade shortfall0.04336 pp

Calculation inputs

Live updates

Kinetics
m³/(kmol·h)
°C
°C
kJ/mol
0 disables temperature correction
Feed and design target
m³/h
kmol/m³
%
Back to results

Equations and assumptions

Power-law kinetics
−rA = k · CA^n
Temperature adjustment
k = kref exp[(Ea/R)(1/Tref − 1/T)]
Single CSTR
VCSTR = FA₀X / [k CA₀^n (1 − X)^n]
Plug flow
VPFR = ∫₀ˣ FA₀ / (−rA) dX

The ideal model is steady state, isothermal and constant density. It assumes one irreversible power-law reaction and no change in volumetric flow. Enter a rate constant with units for the selected order.

The cascade check divides the PFR volume among equal CSTRs. A separate cascade sizing step computes the volume needed at the target. For second order each tank solves Ci + kτtank Ci² = Ci−1 using a cancellation-safe positive root.

Method references