Worked example

X8 coaxial rotor disk loading & paired thrust loss

Estimate effective disk area and thrust allowance for eight motors on four coaxial 15-inch rotor stacks.

Every motor sits on a paired disk here. The model counts four full disks and applies the 14% allowance to the entire isolated thrust reference before comparing at local density.

Inputs

Rotor bench reference

Sum isolated rotor bench results at the same RPM.

Field conditions & overlap

ISA range covers sea level to 12,000 ft.

Enter a bench-derived loss allowance for the two rotors on each shared disk.

View results

Example results

Local static thrust estimate
8,060 gf
Disk loading
173.32 N/m²
Ideal static thrust per watt
11.74 g/W

Static thrust vs. pressure altitude

Static thrust vs. pressure altitudeThe selected altitude of 457.2 m gives 8,060.03 gf of static thrust. 5,363.206,279.9914.47,196.61,828.88,113.32,743.29,0303,657.6Static thrust · gfPressure altitude · m
The solid trace holds the entered ISA temperature deviation constant. The dashed trace shows ISA.
Sea-level bench thrust per watt
4.26 g/W
Local air density
1.14809 kg/m³
Density altitude
670.3 m
Sea-level bench thrust retained
80.6 %
Effective swept disk area
0.456 m²
Ideal induced power
686.7 W
Total coaxial loss allowance
14 %

Worked math

Equations use metric inputs unless a conventional unit is shown.

  1. Effective disk area

    (8 − 4) × π × (381 mm ÷ 2,000)² = 0.45604 m²

  2. Air density and ratio

    ISA pressure at 457.2 m ÷ (287.05287 × 291.15 K) = 1.14809 kg/m³ · ρ ÷ ρ₀ = 0.93721

  3. Fixed-RPM thrust estimate

    10000 gf × 0.93721 × 0.86 = 8,060.031 gf

  4. Induced power and ideal thrust per watt

    79.042 N × √(T ÷ (2ρA)) = 686.727 W · T in gf ÷ P = 11.737 g/W

  5. Disk loading

    79.042 N ÷ 0.45604 m² = 173.324 N/m²

Model assumptions

ISA pressure at the entered pressure altitude and the actual temperature give dry-air density. Density altitude is the standard-atmosphere altitude with the same density.

At fixed RPM and unchanged thrust coefficient, static thrust scales with density. The model counts each coaxial pair as one swept disk and applies the entered loss only to the thrust share from paired rotors.

The actuator disk result is the ideal induced power at the modeled local thrust. The separate bench thrust-per-watt result uses electrical power measured at sea level.

Frequently asked questions

Why does the X8 example use four swept disks for eight motors?

Each aligned top and bottom rotor pair sweeps the same projected area. Four co-located pairs therefore give four distinct projected disks.

How should I estimate the X8 pair-loss percentage?

Measure the paired stack and comparable isolated rotors at the same test condition. Compare paired thrust with the sum of isolated thrust measurements.