Snap 1550 nm to the 50 GHz grid

Use a rounded wavelength to request the start of an eight-channel 400G plan.

Inputs

Select a grid, enter the first desired channel and set the channel count. The plan advances in frequency for DWDM and in wavelength for CWDM.

Channel grid
nm
LIVE ANATOMY

Optical channel comb

Optical channel combACTIVE SLOTS8CAPACITY3.2TbpsAVG SPACING50GHzEFFICIENCY8bit/s/HzC-band · 50 GHz400 Gbit/s per λ191.3 THz196.1 THzFirst λ 1,550.12 nmGRID SLOT USE0 slots55 available8 requested
Channels fitThe requested channel count fits from the snapped start through the selected grid.

Channel centers

Requested frequency
193.41448903 THz
Requested wavelength
1,550 nm
First active center frequency
193.4 THz
First active center wavelength
1,550.116122 nm
Last active center frequency
193.75 THz
Last active center wavelength
1,547.3159123 nm
First center offset from request
-14.4890323 GHz

Plan capacity

Active channel count
8
Channels in full grid
97
Slots available from first center
55
Mean frequency spacing
50 GHz
Gross spectral efficiency
8 bit/s/Hz
Aggregate gross throughput
3.2 Tbps
Channel center table
ChannelTHznm
1193.41,550.116122
2193.451,549.715472
3193.51,549.315028
4193.551,548.914792
5193.61,548.514762
6193.651,548.114939
7193.71,547.715323
8193.751,547.315912

What to check

Read the snapped wavelength and the signed frequency offset instead of assuming the rounded request is a grid center.

Open the general dwdm & cwdm grid calculator

Formulas and assumptions

Frequency and wavelength

λ(nm) = 299792.458 / f(THz)

The constant is the vacuum speed of light with the wavelength and frequency unit scale applied.

Grid indexing

DWDM f = 193.1 THz + n × spacing; CWDM λ = 1271 nm + 20n nm

The selected start is snapped to the nearest center within this tool’s 191.3–196.1 THz planning window or 18-channel CWDM list.

Aggregate throughput

Capacity (Tbps) = active channels × Gbit/s per channel / 1000

Spectral efficiency divides gross line bitrate by spacing. CWDM uses mean adjacent frequency spacing over active channels, or the nearest neighbor for one channel. Compare actual baud rate, FEC and filter passbands separately.

G.694.1 defines the fixed DWDM grid around 193.1 THz. The C-band endpoints used here define the calculator’s scope. G.694.2 defines nominal CWDM centers at 20 nm increments from 1271 through 1611 nm.

Worked examples

Open a scenario and edit any parameter.