40 channels on the 100 GHz grid

Start at 192.1 THz and use 100 Gbit/s on each selected center.

Inputs

Select a grid, enter the first desired channel and set the channel count. The plan advances in frequency for DWDM and in wavelength for CWDM.

Channel grid
THz
LIVE ANATOMY

Optical channel comb

Optical channel combACTIVE SLOTS40CAPACITY4TbpsAVG SPACING100GHzEFFICIENCY1bit/s/HzC-band · 100 GHz100 Gbit/s per λ191.3 THz196.1 THzFirst λ 1,560.61 nmGRID SLOT USE0 slots41 available40 requested
Channels fitThe requested channel count fits from the snapped start through the selected grid.

Channel centers

Requested frequency
192.1 THz
Requested wavelength
1,560.60623634 nm
First active center frequency
192.1 THz
First active center wavelength
1,560.6062363 nm
Last active center frequency
196 THz
Last active center wavelength
1,529.5533571 nm
First center offset from request
0 GHz

Plan capacity

Active channel count
40
Channels in full grid
49
Slots available from first center
41
Mean frequency spacing
100 GHz
Gross spectral efficiency
1 bit/s/Hz
Aggregate gross throughput
4 Tbps
Channel center table
ChannelTHznm
1192.11,560.606236
2192.21,559.794266
3192.31,558.983141
4192.41,558.172859
5192.51,557.363418
6192.61,556.554818
7192.71,555.747058
8192.81,554.940135
9192.91,554.134049
101931,553.328798
11193.11,552.524381
12193.21,551.720797
13193.31,550.918044
14193.41,550.116122
15193.51,549.315028
16193.61,548.514762
17193.71,547.715323
18193.81,546.916708
19193.91,546.118917
201941,545.321948
21194.11,544.525801
22194.21,543.730474
23194.31,542.935965
24194.41,542.142274
25194.51,541.349398
26194.61,540.557338
27194.71,539.766091
28194.81,538.975657
29194.91,538.186034
301951,537.397221
31195.11,536.609216
32195.21,535.822018
33195.31,535.035627
34195.41,534.250041
35195.51,533.465258
36195.61,532.681278
37195.71,531.898099
38195.81,531.11572
39195.91,530.33414
401961,529.553357

What to check

The plan fits forty centers through 196.0 THz.

Open the general dwdm & cwdm grid calculator

Formulas and assumptions

Frequency and wavelength

λ(nm) = 299792.458 / f(THz)

The constant is the vacuum speed of light with the wavelength and frequency unit scale applied.

Grid indexing

DWDM f = 193.1 THz + n × spacing; CWDM λ = 1271 nm + 20n nm

The selected start is snapped to the nearest center within this tool’s 191.3–196.1 THz planning window or 18-channel CWDM list.

Aggregate throughput

Capacity (Tbps) = active channels × Gbit/s per channel / 1000

Spectral efficiency divides gross line bitrate by spacing. CWDM uses mean adjacent frequency spacing over active channels, or the nearest neighbor for one channel. Compare actual baud rate, FEC and filter passbands separately.

G.694.1 defines the fixed DWDM grid around 193.1 THz. The C-band endpoints used here define the calculator’s scope. G.694.2 defines nominal CWDM centers at 20 nm increments from 1271 through 1611 nm.