Full 25 GHz C-band planning window

Count every center in the selected band at 25 GHz and 800 Gbit/s per channel.

Inputs

Select a grid, enter the first desired channel and set the channel count. The plan advances in frequency for DWDM and in wavelength for CWDM.

Channel grid
THz
LIVE ANATOMY

Optical channel comb

Optical channel combACTIVE SLOTS193CAPACITY154.4TbpsAVG SPACING25GHzEFFICIENCY32bit/s/HzC-band · 25 GHz800 Gbit/s per λ191.3 THz196.1 THzFirst λ 1,567.13 nmGRID SLOT USE0 slots193 available193 requested
Channels fitThe requested channel count fits from the snapped start through the selected grid.

Channel centers

Requested frequency
191.3 THz
Requested wavelength
1,567.13255619 nm
First active center frequency
191.3 THz
First active center wavelength
1,567.1325562 nm
Last active center frequency
196.1 THz
Last active center wavelength
1,528.7733707 nm
First center offset from request
-2.842e-11 GHz

Plan capacity

Active channel count
193
Channels in full grid
193
Slots available from first center
193
Mean frequency spacing
25 GHz
Gross spectral efficiency
32 bit/s/Hz
Aggregate gross throughput
154.4 Tbps
Channel center table
ChannelTHznm
1191.31,567.132556
2191.3251,566.927783
3191.351,566.723062
4191.3751,566.518396
5191.41,566.313783
6191.4251,566.109223
7191.451,565.904717
8191.4751,565.700264
9191.51,565.495864
10191.5251,565.291518
11191.551,565.087225
12191.5751,564.882986
13191.61,564.6788
14191.6251,564.474667
15191.651,564.270587
16191.6751,564.066561
17191.71,563.862587
18191.7251,563.658667
19191.751,563.454801
20191.7751,563.250987
21191.81,563.047226
22191.8251,562.843519
23191.851,562.639864
24191.8751,562.436263
25191.91,562.232715
26191.9251,562.02922
27191.951,561.825778
28191.9751,561.622388
291921,561.419052
30192.0251,561.215769
31192.051,561.012538
32192.0751,560.809361
33192.11,560.606236
34192.1251,560.403165
35192.151,560.200146
36192.1751,559.99718
37192.21,559.794266
38192.2251,559.591406
39192.251,559.388598
40192.2751,559.185843
41192.31,558.983141
42192.3251,558.780491
43192.351,558.577894
44192.3751,558.37535
45192.41,558.172859
46192.4251,557.97042
47192.451,557.768033
48192.4751,557.565699
49192.51,557.363418
50192.5251,557.161189
51192.551,556.959013
52192.5751,556.75689
53192.61,556.554818
54192.6251,556.352799
55192.651,556.150833
56192.6751,555.948919
57192.71,555.747058
58192.7251,555.545248
59192.751,555.343492
60192.7751,555.141787
61192.81,554.940135
62192.8251,554.738535
63192.851,554.536987
64192.8751,554.335492
65192.91,554.134049
66192.9251,553.932658
67192.951,553.731319
68192.9751,553.530032
691931,553.328798
70193.0251,553.127616
71193.051,552.926485
72193.0751,552.725407
73193.11,552.524381
74193.1251,552.323407
75193.151,552.122485
76193.1751,551.921615
77193.21,551.720797
78193.2251,551.520031
79193.251,551.319317
80193.2751,551.118655
81193.31,550.918044
82193.3251,550.717486
83193.351,550.51698
84193.3751,550.316525
85193.41,550.116122
86193.4251,549.915771
87193.451,549.715472
88193.4751,549.515224
89193.51,549.315028
90193.5251,549.114884
91193.551,548.914792
92193.5751,548.714751
93193.61,548.514762
94193.6251,548.314825
95193.651,548.114939
96193.6751,547.915105
97193.71,547.715323
98193.7251,547.515592
99193.751,547.315912
100193.7751,547.116284
101193.81,546.916708
102193.8251,546.717183
103193.851,546.51771
104193.8751,546.318288
105193.91,546.118917
106193.9251,545.919598
107193.951,545.72033
108193.9751,545.521114
1091941,545.321948
110194.0251,545.122835
111194.051,544.923772
112194.0751,544.724761
113194.11,544.525801
114194.1251,544.326892
115194.151,544.128035
116194.1751,543.929229
117194.21,543.730474
118194.2251,543.53177
119194.251,543.333117
120194.2751,543.134516
121194.31,542.935965
122194.3251,542.737466
123194.351,542.539017
124194.3751,542.34062
125194.41,542.142274
126194.4251,541.943978
127194.451,541.745734
128194.4751,541.547541
129194.51,541.349398
130194.5251,541.151307
131194.551,540.953267
132194.5751,540.755277
133194.61,540.557338
134194.6251,540.35945
135194.651,540.161613
136194.6751,539.963827
137194.71,539.766091
138194.7251,539.568407
139194.751,539.370773
140194.7751,539.17319
141194.81,538.975657
142194.8251,538.778175
143194.851,538.580744
144194.8751,538.383364
145194.91,538.186034
146194.9251,537.988755
147194.951,537.791526
148194.9751,537.594348
1491951,537.397221
150195.0251,537.200144
151195.051,537.003117
152195.0751,536.806141
153195.11,536.609216
154195.1251,536.412341
155195.151,536.215516
156195.1751,536.018742
157195.21,535.822018
158195.2251,535.625345
159195.251,535.428722
160195.2751,535.23215
161195.31,535.035627
162195.3251,534.839155
163195.351,534.642734
164195.3751,534.446362
165195.41,534.250041
166195.4251,534.05377
167195.451,533.857549
168195.4751,533.661379
169195.51,533.465258
170195.5251,533.269188
171195.551,533.073168
172195.5751,532.877198
173195.61,532.681278
174195.6251,532.485408
175195.651,532.289589
176195.6751,532.093819
177195.71,531.898099
178195.7251,531.702429
179195.751,531.50681
180195.7751,531.31124
181195.81,531.11572
182195.8251,530.92025
183195.851,530.72483
184195.8751,530.52946
185195.91,530.33414
186195.9251,530.138869
187195.951,529.943649
188195.9751,529.748478
1891961,529.553357
190196.0251,529.358286
191196.051,529.163264
192196.0751,528.968293
193196.11,528.773371

What to check

The gross spectral efficiency describes the plan. Transceiver and filter specifications determine whether it is feasible.

Open the general dwdm & cwdm grid calculator

Formulas and assumptions

Frequency and wavelength

λ(nm) = 299792.458 / f(THz)

The constant is the vacuum speed of light with the wavelength and frequency unit scale applied.

Grid indexing

DWDM f = 193.1 THz + n × spacing; CWDM λ = 1271 nm + 20n nm

The selected start is snapped to the nearest center within this tool’s 191.3–196.1 THz planning window or 18-channel CWDM list.

Aggregate throughput

Capacity (Tbps) = active channels × Gbit/s per channel / 1000

Spectral efficiency divides gross line bitrate by spacing. CWDM uses mean adjacent frequency spacing over active channels, or the nearest neighbor for one channel. Compare actual baud rate, FEC and filter passbands separately.

G.694.1 defines the fixed DWDM grid around 193.1 THz. The C-band endpoints used here define the calculator’s scope. G.694.2 defines nominal CWDM centers at 20 nm increments from 1271 through 1611 nm.

Worked examples