Frequency and wavelength
λ(nm) = 299792.458 / f(THz)
The constant is the vacuum speed of light with the wavelength and frequency unit scale applied.
Fill the calculator’s 191.3–196.1 THz band with equal grid steps.
| Channel | THz | nm |
|---|---|---|
| 1 | 191.3 | 1,567.132556 |
| 2 | 191.35 | 1,566.723062 |
| 3 | 191.4 | 1,566.313783 |
| 4 | 191.45 | 1,565.904717 |
| 5 | 191.5 | 1,565.495864 |
| 6 | 191.55 | 1,565.087225 |
| 7 | 191.6 | 1,564.6788 |
| 8 | 191.65 | 1,564.270587 |
| 9 | 191.7 | 1,563.862587 |
| 10 | 191.75 | 1,563.454801 |
| 11 | 191.8 | 1,563.047226 |
| 12 | 191.85 | 1,562.639864 |
| 13 | 191.9 | 1,562.232715 |
| 14 | 191.95 | 1,561.825778 |
| 15 | 192 | 1,561.419052 |
| 16 | 192.05 | 1,561.012538 |
| 17 | 192.1 | 1,560.606236 |
| 18 | 192.15 | 1,560.200146 |
| 19 | 192.2 | 1,559.794266 |
| 20 | 192.25 | 1,559.388598 |
| 21 | 192.3 | 1,558.983141 |
| 22 | 192.35 | 1,558.577894 |
| 23 | 192.4 | 1,558.172859 |
| 24 | 192.45 | 1,557.768033 |
| 25 | 192.5 | 1,557.363418 |
| 26 | 192.55 | 1,556.959013 |
| 27 | 192.6 | 1,556.554818 |
| 28 | 192.65 | 1,556.150833 |
| 29 | 192.7 | 1,555.747058 |
| 30 | 192.75 | 1,555.343492 |
| 31 | 192.8 | 1,554.940135 |
| 32 | 192.85 | 1,554.536987 |
| 33 | 192.9 | 1,554.134049 |
| 34 | 192.95 | 1,553.731319 |
| 35 | 193 | 1,553.328798 |
| 36 | 193.05 | 1,552.926485 |
| 37 | 193.1 | 1,552.524381 |
| 38 | 193.15 | 1,552.122485 |
| 39 | 193.2 | 1,551.720797 |
| 40 | 193.25 | 1,551.319317 |
| 41 | 193.3 | 1,550.918044 |
| 42 | 193.35 | 1,550.51698 |
| 43 | 193.4 | 1,550.116122 |
| 44 | 193.45 | 1,549.715472 |
| 45 | 193.5 | 1,549.315028 |
| 46 | 193.55 | 1,548.914792 |
| 47 | 193.6 | 1,548.514762 |
| 48 | 193.65 | 1,548.114939 |
| 49 | 193.7 | 1,547.715323 |
| 50 | 193.75 | 1,547.315912 |
| 51 | 193.8 | 1,546.916708 |
| 52 | 193.85 | 1,546.51771 |
| 53 | 193.9 | 1,546.118917 |
| 54 | 193.95 | 1,545.72033 |
| 55 | 194 | 1,545.321948 |
| 56 | 194.05 | 1,544.923772 |
| 57 | 194.1 | 1,544.525801 |
| 58 | 194.15 | 1,544.128035 |
| 59 | 194.2 | 1,543.730474 |
| 60 | 194.25 | 1,543.333117 |
| 61 | 194.3 | 1,542.935965 |
| 62 | 194.35 | 1,542.539017 |
| 63 | 194.4 | 1,542.142274 |
| 64 | 194.45 | 1,541.745734 |
| 65 | 194.5 | 1,541.349398 |
| 66 | 194.55 | 1,540.953267 |
| 67 | 194.6 | 1,540.557338 |
| 68 | 194.65 | 1,540.161613 |
| 69 | 194.7 | 1,539.766091 |
| 70 | 194.75 | 1,539.370773 |
| 71 | 194.8 | 1,538.975657 |
| 72 | 194.85 | 1,538.580744 |
| 73 | 194.9 | 1,538.186034 |
| 74 | 194.95 | 1,537.791526 |
| 75 | 195 | 1,537.397221 |
| 76 | 195.05 | 1,537.003117 |
| 77 | 195.1 | 1,536.609216 |
| 78 | 195.15 | 1,536.215516 |
| 79 | 195.2 | 1,535.822018 |
| 80 | 195.25 | 1,535.428722 |
| 81 | 195.3 | 1,535.035627 |
| 82 | 195.35 | 1,534.642734 |
| 83 | 195.4 | 1,534.250041 |
| 84 | 195.45 | 1,533.857549 |
| 85 | 195.5 | 1,533.465258 |
| 86 | 195.55 | 1,533.073168 |
| 87 | 195.6 | 1,532.681278 |
| 88 | 195.65 | 1,532.289589 |
| 89 | 195.7 | 1,531.898099 |
| 90 | 195.75 | 1,531.50681 |
| 91 | 195.8 | 1,531.11572 |
| 92 | 195.85 | 1,530.72483 |
| 93 | 195.9 | 1,530.33414 |
| 94 | 195.95 | 1,529.943649 |
| 95 | 196 | 1,529.553357 |
| 96 | 196.05 | 1,529.163264 |
| 97 | 196.1 | 1,528.773371 |
Inclusive endpoints add one channel to the number of 50 GHz intervals.
Open the general dwdm & cwdm grid calculatorλ(nm) = 299792.458 / f(THz)
The constant is the vacuum speed of light with the wavelength and frequency unit scale applied.
DWDM f = 193.1 THz + n × spacing; CWDM λ = 1271 nm + 20n nm
The selected start is snapped to the nearest center within this tool’s 191.3–196.1 THz planning window or 18-channel CWDM list.
Capacity (Tbps) = active channels × Gbit/s per channel / 1000
Spectral efficiency divides gross line bitrate by spacing. CWDM uses mean adjacent frequency spacing over active channels, or the nearest neighbor for one channel. Compare actual baud rate, FEC and filter passbands separately.
G.694.1 defines the fixed DWDM grid around 193.1 THz. The C-band endpoints used here define the calculator’s scope. G.694.2 defines nominal CWDM centers at 20 nm increments from 1271 through 1611 nm.
Open a scenario and edit any parameter.
FiberOpticLab
Channels fit. The requested channel count fits from the snapped start through the selected grid.
Follow IEC 60825-2 and ANSI Z136.2 procedures. Never inspect an energized fiber or connector with your eye or an optical magnifier. Verify the installed link with a calibrated power meter and field OTDR at the relevant wavelengths, using appropriate launch and receive fibers and a safe test setup.
Correct the inputs to print an engineering report.