Full 50 GHz C-band planning window

Fill the calculator’s 191.3–196.1 THz band with equal grid steps.

Inputs

Select a grid, enter the first desired channel and set the channel count. The plan advances in frequency for DWDM and in wavelength for CWDM.

Channel grid
THz
LIVE ANATOMY

Optical channel comb

Optical channel combACTIVE SLOTS97CAPACITY38.8TbpsAVG SPACING50GHzEFFICIENCY8bit/s/HzC-band · 50 GHz400 Gbit/s per λ191.3 THz196.1 THzFirst λ 1,567.13 nmGRID SLOT USE0 slots97 available97 requested
Channels fitThe requested channel count fits from the snapped start through the selected grid.

Channel centers

Requested frequency
191.3 THz
Requested wavelength
1,567.13255619 nm
First active center frequency
191.3 THz
First active center wavelength
1,567.1325562 nm
Last active center frequency
196.1 THz
Last active center wavelength
1,528.7733707 nm
First center offset from request
-2.842e-11 GHz

Plan capacity

Active channel count
97
Channels in full grid
97
Slots available from first center
97
Mean frequency spacing
50 GHz
Gross spectral efficiency
8 bit/s/Hz
Aggregate gross throughput
38.8 Tbps
Channel center table
ChannelTHznm
1191.31,567.132556
2191.351,566.723062
3191.41,566.313783
4191.451,565.904717
5191.51,565.495864
6191.551,565.087225
7191.61,564.6788
8191.651,564.270587
9191.71,563.862587
10191.751,563.454801
11191.81,563.047226
12191.851,562.639864
13191.91,562.232715
14191.951,561.825778
151921,561.419052
16192.051,561.012538
17192.11,560.606236
18192.151,560.200146
19192.21,559.794266
20192.251,559.388598
21192.31,558.983141
22192.351,558.577894
23192.41,558.172859
24192.451,557.768033
25192.51,557.363418
26192.551,556.959013
27192.61,556.554818
28192.651,556.150833
29192.71,555.747058
30192.751,555.343492
31192.81,554.940135
32192.851,554.536987
33192.91,554.134049
34192.951,553.731319
351931,553.328798
36193.051,552.926485
37193.11,552.524381
38193.151,552.122485
39193.21,551.720797
40193.251,551.319317
41193.31,550.918044
42193.351,550.51698
43193.41,550.116122
44193.451,549.715472
45193.51,549.315028
46193.551,548.914792
47193.61,548.514762
48193.651,548.114939
49193.71,547.715323
50193.751,547.315912
51193.81,546.916708
52193.851,546.51771
53193.91,546.118917
54193.951,545.72033
551941,545.321948
56194.051,544.923772
57194.11,544.525801
58194.151,544.128035
59194.21,543.730474
60194.251,543.333117
61194.31,542.935965
62194.351,542.539017
63194.41,542.142274
64194.451,541.745734
65194.51,541.349398
66194.551,540.953267
67194.61,540.557338
68194.651,540.161613
69194.71,539.766091
70194.751,539.370773
71194.81,538.975657
72194.851,538.580744
73194.91,538.186034
74194.951,537.791526
751951,537.397221
76195.051,537.003117
77195.11,536.609216
78195.151,536.215516
79195.21,535.822018
80195.251,535.428722
81195.31,535.035627
82195.351,534.642734
83195.41,534.250041
84195.451,533.857549
85195.51,533.465258
86195.551,533.073168
87195.61,532.681278
88195.651,532.289589
89195.71,531.898099
90195.751,531.50681
91195.81,531.11572
92195.851,530.72483
93195.91,530.33414
94195.951,529.943649
951961,529.553357
96196.051,529.163264
97196.11,528.773371

What to check

Inclusive endpoints add one channel to the number of 50 GHz intervals.

Open the general dwdm & cwdm grid calculator

Formulas and assumptions

Frequency and wavelength

λ(nm) = 299792.458 / f(THz)

The constant is the vacuum speed of light with the wavelength and frequency unit scale applied.

Grid indexing

DWDM f = 193.1 THz + n × spacing; CWDM λ = 1271 nm + 20n nm

The selected start is snapped to the nearest center within this tool’s 191.3–196.1 THz planning window or 18-channel CWDM list.

Aggregate throughput

Capacity (Tbps) = active channels × Gbit/s per channel / 1000

Spectral efficiency divides gross line bitrate by spacing. CWDM uses mean adjacent frequency spacing over active channels, or the nearest neighbor for one channel. Compare actual baud rate, FEC and filter passbands separately.

G.694.1 defines the fixed DWDM grid around 193.1 THz. The C-band endpoints used here define the calculator’s scope. G.694.2 defines nominal CWDM centers at 20 nm increments from 1271 through 1611 nm.

Worked examples

Open a scenario and edit any parameter.