Matched IOR over 10 km

Both the true and tester indices are identical. Use a 50 ns pulse and zero added event recovery.

Inputs

Set the true group index for the fiber and wavelength, then enter the tester setting. Use instrument-specific recovery allowances where available.

Fiber and instrument
km
ns
Resolution and tolerance
ns
ns
m
LIVE ANATOMY

OTDR reflection and recovery

OTDR reflection and recoveryONE WAY48.974µsRETURN97.948µsEVENT DZ5.105mATTEN. DZ9.699m50 ns pulseRecovery estimatedPulse5.1 mEvent DZ5.1 mAtten. DZ9.7 mDISTANCE ERROR BUDGET0 m10 m limit10 m left
IOR error within targetThe entered distance-error tolerance covers the calculated index mismatch.

Propagation

One-way latency
48.9739 µs
Round-trip latency
97.9478 µs
True optical span
10 km
Indicated optical span
10 km
Signed distance error
0 m
Signed percent error
0 %

Pulse and reflection estimates

Pulse footprint
5.10476 m
Event dead zone estimate
5.10476 m
Attenuation dead zone estimate
9.69905 m

What to check

Matched IOR removes this systematic distance error while pulse width still limits resolution.

Open the general otdr latency & dead zones calculator

Formulas and assumptions

Time of flight

t₁ = L × ng / c; tRT = 2 × t₁

The vacuum speed is 299,792.458 km/s. Use group index because the pulse envelope determines round-trip timing.

Pulse resolution and dead zones

dz ≈ c × (pulse width + recovery allowance) / (2 × ng)

The factor of two converts return time to one-way range. EDZ estimates the distance to separate events. ADZ estimates the distance to measure a subsequent loss. Recovery allowances model the instrument response and reflection.

IOR mismatch

Lindicated = Ltrue × ng / ntester; error = Lindicated − Ltrue

A low tester index makes an unchanged time of flight look like a longer distance. Use the signed error to understand the direction.

The SMF-28 and OM4 indices are illustrative group index presets. Real dead zones depend on reflectance, receiver saturation, instrument processing and test setup. Treat calculated EDZ and ADZ as estimates and check actual instrument specifications and traces.

Worked examples

Open a scenario and edit any parameter.