Inverse in the southwest quadrant

Convert a southwest offset into the correct whole-circle azimuth and bearing.

More examples

Field inputs

Switching the unit converts the inputs.

Coordinate inverse
Forward polar
Angle conversions

Use decimal degrees, DMS, a quadrant bearing, or a cardinal such as W where a direction is requested.

Survey anatomy

North-up coordinate vectors

Edit inputs
North-up coordinate vectorsLive plot with four readings and a check bar. North-clockwise sweep. 233.13° / 360°.DISTANCE100mINV. AZIMUTH233.1301°FORWARD N4,893.8366mFORWARD E2,375.0289mNESWINVERSEFORWARDP1P2F0F1North-clockwise sweep233.13° / 360°
Diagram proportions adapt to the inputs. Use the computed readings for field dimensions.

Computed results

233.13° / 360°

Coordinate inverse

Horizontal distance
100m
Δ Northing
−60m
Δ Easting
−80m
Azimuth
233.130102°
Quadrant bearing
S 53° 07′ 48.37″ W

Forward polar

New northing
4,893.8366m
New easting
2,375.02887m
Δ Northing
−106.1634m
Δ Easting
75.02887m
Azimuth
144.75°
Quadrant bearing
S 35° 15′ 00.00″ E

Angle conversions

Whole-circle azimuth
317.741667°
Quadrant bearing
N 42° 15′ 30.00″ W
Signed decimal degrees
−0.504167°
Signed DMS
−0° 30′ 15.00″

Worked check

The −60 m and −80 m offsets put the line southwest. The azimuth is 180° plus the acute angle from south toward west.

Distance (m)
100
Azimuth (°)
233.1301024
Quadrant bearing
S 53° 07′ 48.37″ W

These checks describe the original example. Reset restores the original inputs.

Formulas and conventions

Inverse from two points

ΔN = N₂ − N₁ · ΔE = E₂ − E₁ · d = √(ΔN² + ΔE²)

Compute atan2(ΔE, ΔN) in degrees and wrap into [0°, 360°). Bearings are clockwise from grid north for azimuth and measured from north or south toward east or west in quadrant notation. Coincident points have no inverse direction.

Project a polar point

N₂ = N₁ + d cos(α) · E₂ = E₁ + d sin(α)

Use horizontal distance in the same working unit as the coordinates. Both sets of coordinates must share the same planar grid and north reference.

Convert degrees, minutes and seconds

DD = sign × (degrees + minutes ÷ 60 + seconds ÷ 3600)

A minus sign applies to the whole angle, including a degree value of zero. The converter rounds published DMS to 0.01″ and carries into minutes or degrees where needed.

More worked examples

Open a case to edit its inputs and compare the original checks.

Share editable inputs

The link contains the entered field values. Share it with people who should see those values.