Worked example · Pedalboard Power Budget

A crowded board with too few taps and no 18 V outlet

Two pedals compete for a small compatible 9 V outlet after the sampler claims the 400 mA tap. A separate 18 V boost has no matching rail.

Try this Change the spare 12 V outlet to 18 V and inspect the one conflict that remains on the 9 V rail.

Inputs

View results ↓
%0–100 %
W0.1–500 W

Pedals

Pedal 1
mA1–4,000 mA
Pedal 2
mA1–4,000 mA
Pedal 3
mA1–4,000 mA
Pedal 4
mA1–4,000 mA

Isolated outputs

Tap 1
mA1–4,000 mA
Tap 2
mA1–4,000 mA
Tap 3
mA1–4,000 mA
Tap 4
mA1–4,000 mA
Planned board draw
6.165 W
PSU utilization
44 %
Pedals assigned
2 / 4

Isolated tap loading

Isolated tap loadingSolid bars show assigned draw. The lighter extension shows your current reserve. Each outline is that tap’s rated capacity. TAP / RAILCURRENT + RESERVE1 / 9V130 / 150 mA2 / 9V310 / 400 mA3 / 9V0 / 500 mA4 / 12V0 / 300 mAPLANNED 6.165 W44% of PSU
Solid bars show assigned draw. The lighter extension shows your current reserve. Each outline is that tap’s rated capacity.
  • Flanger: Compatible taps already assigned.
  • Clean boost: No 18 V tap.

Pedal allocation
PedalRail (V)PolarityCurrent (mA)With reserve (mA)WattsTap or reason
Sampler9Center negative3103412.79Tap 2
Flanger9Center negative95104.50.855Compatible taps already assigned
Stereo chorus9Center negative1301431.17Tap 1
Clean boost18Center negative7582.51.35No 18 V tap
Tap inventory
TapRail (V)PolarityCapacity (mA)Pedal
19Center negative150Stereo chorus
29Center negative400Sampler
39Center positive500Spare
412Center negative300Spare
Combined output
Assigned draw (W)Planned draw with reserve (W)
3.966.781
Planned board draw 6.165 W

How the calculation works

Match the rail and polarity first

Each pedal uses one isolated DC tap with matching voltage and polarity. Current plus your reserve must fit that tap’s specified rating at its selected voltage.

Allocate the tightest adequate tap

The allocator checks higher-current pedals first and uses the smallest adequate compatible tap for each. Read the reason beside any unassigned pedal.

Check the combined supply

Add V × A for each pedal. The PSU utilization figure uses the entire planned board, including unassigned pedals. Compare reserved draw with the supply’s simultaneous output limit.

References

Questions at the bench

Which lower-current pedal gets the 150 mA slot on this crowded board?

The 130 mA chorus is processed before the 95 mA flanger and fits the slot with 10% reserve.

How can I see whether a missing rail or a used tap caused a failure?

Read the reason beside the pedal. A missing rail points to voltage availability, while compatible taps already assigned points to the outlet count.