Worked example

Fast delivery of about 2 L

Correct the gas fill pressure to operating temperature, then subtract the gas volume at P2 from its volume at P1 to find usable oil.

Inputs

in³
psi
psi
psi
Gauge pre-charge with the oil side unloaded at the gas fill temperature.
°F
°F

Anatomy

Nitrogen accumulator pressure–volume curve
Nitrogen accumulator pressure–volume curveGAS VOLUME1.751galWARM P01550psiP2 / P02.055:1USABLE OIL30.16%N₂BladderGas pressureP2P1Gas volumePressureReturnTank / suctionPressure ratio / bladder guide51.37%0%100% reference150%

Results

US customary
Required nominal gas volume1.751gal6.628L
Pre-charge at operating temperature1,549.928psi
Gas fill pressure for 90% of P11,515.597psi
Operating pre-charge / P186.107%
Pressure ratio P2 / P02.055:1
Usable oil / nominal volume30.162%
Gas volume at P11.575gal
Gas volume at P21.047gal
Polytropic exponent1.4

Worked calculation

  1. Convert to absolute

    P_abs = P_gauge + 1 atm. At fixed gas volume, P0,op,abs = P0,fill,abs × T_op/T_fill. Use Kelvin for the temperature ratio.

  2. Gas compression

    P × Vⁿ = constant. Use n = 1.0 for a slow isothermal event and n = 1.4 for a fast adiabatic nitrogen event. V(P) = V0 × (P0,op,abs/P_abs)^(1/n).

  3. Usable oil

    ΔV = V(P1) − V(P2). Divide required ΔV by [(P0/P1)^(1/n) − (P0/P2)^(1/n)] to get nominal gas volume. The ratios in the volume equation use absolute pressures.

  4. Pre-charge and pressure ratio

    Compare the operating gauge pre-charge with 80–90% of gauge P1. Check absolute P2/P0 against the selected accumulator limit. A 4:1 limit is a typical bladder guide.

Results for the original example inputs
Pre-charge at operating temperature1,549.928psi
Gas volume at P11.575gal
Gas volume at P21.047gal
Usable oil / nominal volume30.162%
Required nominal gas volume1.751gal
Pressure ratio P2 / P02.055:1

Ideal nitrogen model for preliminary energy-storage sizing. Real gas factors, dead volume, permitted pressure ratio and allowable temperature are product-specific. Consult OEM information for selection and charging.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.