Worked example

Narrow pump-on and pump-off band

A small change in gas volume between 2,200 and 2,500 psi requires a larger nominal vessel for the same oil demand.

Inputs

in³
psi
psi
psi
Gauge pre-charge with the oil side unloaded at the gas fill temperature.
°F
°F

Anatomy

Nitrogen accumulator pressure–volume curve
Nitrogen accumulator pressure–volume curveGAS VOLUME5.549galWARM P01894psiP2 / P01.317:1USABLE OIL7.802%N₂BladderGas pressureP2P1Gas volumePressureReturnTank / suctionPressure ratio / bladder guide32.93%0%100% reference150%

Results

US customary
Required nominal gas volume5.549gal21.005L
Pre-charge at operating temperature1,894.363psi
Gas fill pressure for 90% of P11,964.993psi
Operating pre-charge / P186.107%
Pressure ratio P2 / P01.317:1
Usable oil / nominal volume7.802%
Gas volume at P14.99gal
Gas volume at P24.558gal
Polytropic exponent1.4

Worked calculation

  1. Convert to absolute

    P_abs = P_gauge + 1 atm. At fixed gas volume, P0,op,abs = P0,fill,abs × T_op/T_fill. Use Kelvin for the temperature ratio.

  2. Gas compression

    P × Vⁿ = constant. Use n = 1.0 for a slow isothermal event and n = 1.4 for a fast adiabatic nitrogen event. V(P) = V0 × (P0,op,abs/P_abs)^(1/n).

  3. Usable oil

    ΔV = V(P1) − V(P2). Divide required ΔV by [(P0/P1)^(1/n) − (P0/P2)^(1/n)] to get nominal gas volume. The ratios in the volume equation use absolute pressures.

  4. Pre-charge and pressure ratio

    Compare the operating gauge pre-charge with 80–90% of gauge P1. Check absolute P2/P0 against the selected accumulator limit. A 4:1 limit is a typical bladder guide.

Results for the original example inputs
Pre-charge at operating temperature1,894.363psi
Gas volume at P14.99gal
Gas volume at P24.558gal
Usable oil / nominal volume7.802%
Required nominal gas volume5.549gal
Pressure ratio P2 / P01.317:1

Ideal nitrogen model for preliminary energy-storage sizing. Real gas factors, dead volume, permitted pressure ratio and allowable temperature are product-specific. Consult OEM information for selection and charging.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.