Worked example
Slow delivery of about 2 L
For the same pressure window and oil demand, slow compression uses n = 1.0. Compare nominal volume with the fast-delivery case.
Inputs
Anatomy
Nitrogen accumulator pressure–volume curveResults
US customary| Required nominal gas volume | 1.407gal5.324L |
|---|---|
| Pre-charge at operating temperature | 1,549.928psi |
| Gas fill pressure for 90% of P1 | 1,515.597psi |
| Operating pre-charge / P1 | 86.107% |
| Pressure ratio P2 / P0 | 2.055:1 |
| Usable oil / nominal volume | 37.549% |
| Gas volume at P1 | 1.213gal |
| Gas volume at P2 | 0.685gal |
| Polytropic exponent | 1 |
Worked calculation
Convert to absolute
P_abs = P_gauge + 1 atm. At fixed gas volume, P0,op,abs = P0,fill,abs × T_op/T_fill. Use Kelvin for the temperature ratio.
Gas compression
P × Vⁿ = constant. Use n = 1.0 for a slow isothermal event and n = 1.4 for a fast adiabatic nitrogen event. V(P) = V0 × (P0,op,abs/P_abs)^(1/n).
Usable oil
ΔV = V(P1) − V(P2). Divide required ΔV by [(P0/P1)^(1/n) − (P0/P2)^(1/n)] to get nominal gas volume. The ratios in the volume equation use absolute pressures.
Pre-charge and pressure ratio
Compare the operating gauge pre-charge with 80–90% of gauge P1. Check absolute P2/P0 against the selected accumulator limit. A 4:1 limit is a typical bladder guide.
| Pre-charge at operating temperature | 1,549.928psi |
|---|---|
| Gas volume at P1 | 1.213gal |
| Gas volume at P2 | 0.685gal |
| Usable oil / nominal volume | 37.549% |
| Required nominal gas volume | 1.407gal |
| Pressure ratio P2 / P0 | 2.055:1 |
Ideal nitrogen model for preliminary energy-storage sizing. Real gas factors, dead volume, permitted pressure ratio and allowable temperature are product-specific. Consult OEM information for selection and charging.
The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.