Worked example

Zero differential across the relief path

With no pressure energy dissipated in the modeled branch, both temperature-rise methods return zero. The intensifier calculation still uses its own inlet pressure.

Inputs

:1
psi
GPM
psi
psi
Use the actual differential across the relief valve.
lb/ft³
BTU/lb·°F
°F
°F

Anatomy

Area-ratio intensifier and relief temperature rise
Area-ratio intensifier and relief temperature riseBOOST PRESS.3500psiOUTLET FLOW4GPMOIL TEMP RISE0°FSEAL MARGIN55°FInlet pistonBoosted oilRelief valveOil warmingReturnPressureReturnTank / suctionBoost pressure / entered rating87.5%0%100% reference150%

Results

US customary
Ideal boosted pressure3,500psi241.317bar
Ideal high-side flow4GPM15.142LPM
Ideal transmitted power8.167HP
Calculated single-pass rise0°F0°C
Field estimate · ΔP/1500°F0°C
Oil temperature after relief95°F
Temperature below seal limit55°F

Worked calculation

  1. Pressure multiplication

    R = A_low/A_high. Ideal pressure out = R × pressure in. Ideal flow out = flow in/R. Pressure × flow is conserved in this model.

  2. Single-pass heat balance

    ΔT = ΔP/(ρ × c_p) with Pa, kg/m³ and J/kg·K. Add the resulting temperature difference to the inlet temperature.

  3. Field approximation

    ΔT (°F) ≈ ΔP (psi)/150. Compare to the calculation using the entered oil properties and check the seal limit at the predicted outlet temperature.

Results for the original example inputs
Ideal boosted pressure3,500psi
Ideal high-side flow4GPM
Calculated single-pass rise0°F
Field estimate · ΔP/1500°F
Oil temperature after relief95°F
Temperature below seal limit55°F

Uses ideal same-stroke area multiplication and negligible inlet backpressure on the intensifier’s return side. Real output depends on leakage and refill duty. The relief model treats lost pressure energy as sensible heat in a single oil pass.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.