Worked example
Zero differential across the relief path
With no pressure energy dissipated in the modeled branch, both temperature-rise methods return zero. The intensifier calculation still uses its own inlet pressure.
Inputs
Anatomy
Area-ratio intensifier and relief temperature riseResults
US customary| Ideal boosted pressure | 3,500psi241.317bar |
|---|---|
| Ideal high-side flow | 4GPM15.142LPM |
| Ideal transmitted power | 8.167HP |
| Calculated single-pass rise | 0°F0°C |
| Field estimate · ΔP/150 | 0°F0°C |
| Oil temperature after relief | 95°F |
| Temperature below seal limit | 55°F |
Worked calculation
Pressure multiplication
R = A_low/A_high. Ideal pressure out = R × pressure in. Ideal flow out = flow in/R. Pressure × flow is conserved in this model.
Single-pass heat balance
ΔT = ΔP/(ρ × c_p) with Pa, kg/m³ and J/kg·K. Add the resulting temperature difference to the inlet temperature.
Field approximation
ΔT (°F) ≈ ΔP (psi)/150. Compare to the calculation using the entered oil properties and check the seal limit at the predicted outlet temperature.
| Ideal boosted pressure | 3,500psi |
|---|---|
| Ideal high-side flow | 4GPM |
| Calculated single-pass rise | 0°F |
| Field estimate · ΔP/150 | 0°F |
| Oil temperature after relief | 95°F |
| Temperature below seal limit | 55°F |
Uses ideal same-stroke area multiplication and negligible inlet backpressure on the intensifier’s return side. Real output depends on leakage and refill duty. The relief model treats lost pressure energy as sensible heat in a single oil pass.
The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.