Deck hardware · Worked example

8 mm Dyneema SK78 with an Eye Splice: Working Load

Use the Marlow D12 78 sample’s minimum spliced strength at 8 mm and an 8:1 model factor to estimate working load without a shackle.

Example result 8.3 kN Estimated rope working load

Inputs

Rope and boat
m
Shackle
Shackle
Rope ratings
Rope ratings
kN
Use the product’s comparable spliced minimum. Zero uses the reference model.
%
Zero uses an illustrative knot factor, except for Dyneema knots which need a documented factor.

Estimated rope working load

8.3 kN
Rope and shackle load estimatesRope reference 66.3 kN. Assembly working load 8.3 kN. Rope reference66.3 kNAfter termination66.3 kNRope working load8.3 kNShackle working load—Assembly working load · 8.3 kN
Reference and reduced working loads
Estimated assembly working load
8.3 kN
Rope reference breaking load
66.3 kN
Retained termination strength
100%
Estimated terminated breaking load
66.3 kN
Shackle published breaking load
—
Shackle marine working load cap
—
Estimated shackle working load
—
Starting nylon dock-line diameter
15.9 mm
Bow / stern dock-line length
6.9 m
Approximate spring-line length
10.4 m
Reference rope
Marlow D12 78
Reference shackle
No shackle

Reference rope strength already accounts for a specified splice. Check the correct splice for your actual line.

Passage sheet

Worked calculation

These steps use the original example inputs.

  1. Rope reference minimumMarlow D12 78 · 14,915 lbf
  2. Estimated rope working load14,915 × 100% ÷ 8 = 1,864.4 lbf
  3. Starting dock line5/8 in nylon · ⅔ × 34 ft = 22.67 ft bow or stern line.

The baseline is a declared minimum for a specified splice. Match the splice, construction and test basis when comparing with your own product.

See formulas and assumptions for rope, shackle & dock lines

Model assumptions

For planning only. Do not use these estimates for lifting, towing, safety of life, permanent mooring or shock loads. Check the actual product’s certified ratings, termination, load direction, wet strength, chafe and dock conditions.

Frequently asked questions

Why is the 8 mm SK78 preset based on minimum spliced strength?

A linear breaking test and a completed splice have different ratings in the datasheet. The spliced minimum matches this completed termination.

Should the 8 mm SK78 load estimate determine nylon dock-line sizing?

The dock-line section gives a separate nylon starting size by boat length. Dock lines also need stretch, chafe protection and a suitable lead.

References