MotionMechLab

12-tooth 20° spur gear undercut and contact ratio

Screen a standard 12T pinion at 20 degrees and see why nominal contact ratio alone cannot clear a gear pair.

Jump to results ↓

Inputs

Tooth geometry
mm
°
Mating gears
T
T

Results

Preset estimate
Nominal center distance
24mm
  • The smaller gear falls below the 18-tooth undercut screen for this pressure angle and a standard full-depth rack cutter.
  • Nominal contact extends beyond a base-circle tangent. Check interference and the actual tooth profile.
External spur gear pitch, base and outside circles with the line of actionZ1 12TZ2 36T24 mm C–C
Orange rings are pitch circles. The gray rings show base and outside diameters. Geometry assumes standard unshifted teeth.
Center distance (imperial)
0.944882 in
Driven / driver ratio
3:1
Transverse contact ratio
1.5564
Metric module
1 mm
Diametral pitch
25.4 T/in
Circular pitch
3.1416 mm
Addendum
1 mm
Dedendum
1.25 mm
Driver pitch diameter
12 mm
Driver outside (addendum) diameter
14 mm
Driver root (dedendum) diameter
9.5 mm
Driver base diameter
11.2763 mm
Driven pitch diameter
36 mm
Driven outside (addendum) diameter
38 mm
Driven root (dedendum) diameter
33.5 mm
Driven base diameter
33.8289 mm

Worked example

A module 1, 12T and 36T pair lays out at 24 mm centers. At 20° the unshifted 12T pinion falls below the theoretical rack-cut undercut threshold. Contact on the pinion may extend beyond the usable involute.

Compare profiles before committing to a pinion this small. A designer can consider a different tooth count, pressure angle or calculated profile shift. The visible pitch circles still give useful nominal packaging dimensions.

Nominal center distance 24 mm

Formulas

  • Module (mm) = 25.4 / DP
  • Pitch diameter d = m Z
  • Outside diameter = d + 2m
  • Root diameter = d − 2.5m
  • Center distance = (d₁ + d₂) / 2
  • Base diameter = d cos α
  • Contact ratio = [√(rₐ₁² − rᵦ₁²) + √(rₐ₂² − rᵦ₂²) − C sin α] / (π m cos α)

References

Frequently asked questions

Can I clear a 12T pinion because its calculated contact ratio exceeds one?

Check usable involute and interference first. The displayed ratio uses untrimmed nominal geometry and can include invalid portions of the line of contact.

Does raising module alone remove the 12T undercut warning?

No. For standard unshifted teeth the screen depends on tooth count and pressure angle, which do not change with module.