Estimate GFS space for 80 TB changing at 6% per day

Calculate how weekly and monthly full points dominate a high-change 80 TB backup set with modest deduplication.

Try these inputs

Worked calculation

  1. The changed data is 80 × 0.06 = 4.8 TB per day. Seven daily slots contribute 33.6 TB.
  2. Two weekly fulls, a monthly full and the active copy contribute 4 × 80 = 320 TB.
  3. Divide 353.6 TB logical by 1.5 for about 235.73 TB physical. At one cent per decimal GB-month, the estimate is about $2,357.33.

Inputs

Dataset
Retained copies
Space reduction

Calculated in your browser

Results

Physical storage
235.7333 TB
Logical storage
353.6 TB
Monthly storage cost
$2,357.33

Cumulative GFS storage

Cumulative GFS storageEach dot adds another retention tier after deduplication and compression. The horizontal axis groups restore points by policy tier.Physical storage · 235.7333 TB0 TBActive full: 53.3333 TBDaily incremental: 22.4 TBWeekly full: 106.6667 TBMonthly full: 53.3333 TBYearly full: 0 TBFullDailyWeeklyMonthlyYearly
  • Stored after space reduction
Each dot adds another retention tier after deduplication and compression. The horizontal axis groups restore points by policy tier.
Combined reduction
1.5:1
Daily change
6%
Stored GB
235,733.333
Per GB-month
$0.01
Retention storage
TierCopiesLogicalPhysical
Active full180 TB53.3333 TB
Daily incremental733.6 TB22.4 TB
Weekly full2160 TB106.6667 TB
Monthly full180 TB53.3333 TB
Yearly full00 TB0 TB

Questions

What is the incremental logical cost of another daily point at 6% change?

Add 4.8 TB logical under the constant change rate, or 3.2 TB physical at 1.5:1.

Would trimming one weekly full save more space than trimming one daily point?

In this model, yes. A weekly full is 80 TB logical while another daily increment is 4.8 TB.