Estimate GFS space for 80 TB changing at 6% per day
Calculate how weekly and monthly full points dominate a high-change 80 TB backup set with modest deduplication.
Try these inputsWorked calculation
- The changed data is 80 × 0.06 = 4.8 TB per day. Seven daily slots contribute 33.6 TB.
- Two weekly fulls, a monthly full and the active copy contribute 4 × 80 = 320 TB.
- Divide 353.6 TB logical by 1.5 for about 235.73 TB physical. At one cent per decimal GB-month, the estimate is about $2,357.33.
Results
- Physical storage
- 235.7333 TB
- Logical storage
- 353.6 TB
- Monthly storage cost
- $2,357.33
Cumulative GFS storage
- Stored after space reduction
- Combined reduction
- 1.5:1
- Daily change
- 6%
- Stored GB
- 235,733.333
- Per GB-month
- $0.01
| Tier | Copies | Logical | Physical |
|---|---|---|---|
| Active full | 1 | 80 TB | 53.3333 TB |
| Daily incremental | 7 | 33.6 TB | 22.4 TB |
| Weekly full | 2 | 160 TB | 106.6667 TB |
| Monthly full | 1 | 80 TB | 53.3333 TB |
| Yearly full | 0 | 0 TB | 0 TB |
Questions
What is the incremental logical cost of another daily point at 6% change?
Add 4.8 TB logical under the constant change rate, or 3.2 TB physical at 1.5:1.
Would trimming one weekly full save more space than trimming one daily point?
In this model, yes. A weekly full is 80 TB logical while another daily increment is 4.8 TB.