20Hz Audio AC-Coupling RC High-Pass Filter Calculator & Bode Plot

Size DC-blocking audio coupling capacitors and bias resistors for a 15–20 Hz RC high-pass filter, checking bass roll-off and phase shift at 20 Hz and 100 Hz.

Jump to results

Inputs

Filter topology & components
Frequency evaluation

Results

Estimates
−3 dB Cutoff frequency (fc)15.92 Hz
Time constant (τ)
10 ms
Gain at f_test
-2.13 dB (78.2%)
Phase shift at f_test
+38.5°
Settling time (3τ / 5τ)
30 ms / 50 ms
Reactance at f_test
7.96 kΩ
Total impedance |Z|
12.78 kΩ
Bode magnitude plot (0.01·fc to 100·fc)
0 dB -20 dB -40 dB0.01×0.1×fc10×100×fc = 15.92 Hz (−3 dB) · Amber dot: f_test
Frequency response sweep
Frequencyf / fcMagnitude |H|Gain (dB)Phase (°)
159.15 mHz0.01×0.01-40 dB+89.4°
1.59 Hz0.1×0.0995-20.04 dB+84.3°
7.96 Hz0.5×0.4472-6.99 dB+63.4°
15.92 Hz1×0.7071-3.01 dB+45°
31.83 Hz2×0.8944-0.97 dB+26.6°
159.15 Hz10×0.995-0.04 dB+5.7°
1.59 kHz100×1-4.34e-4 dB+0.6°

First-order passive filters roll off at −20 dB/decade (−6 dB/octave). Buffer the output if downstream load impedance is less than 10× R.

Block DC offset without attenuating deep bass in audio stages

Line-level audio stages and electret microphone preamps use a series coupling capacitor and shunt bias resistor to block DC offset while passing 20 Hz–20 kHz audio. Placing f_c right at 20 Hz loses 3 dB at 20 Hz; placing f_c around 3–16 Hz preserves sub-bass amplitude and keeps phase shift small across the vocal band.

Evaluate both 20 Hz deep-bass response and 100 Hz mid-bass phase shift directly on the Bode curve.

Formulas

  • f_c = 1 ÷ (2π × 10 kΩ × 1 µF) = 15.92 Hz
  • High-Pass |H(f)| = (f/f_c) ÷ √(1 + (f/f_c)²)
  • Phase(f) = +atan(f_c ÷ f)

Worked example

A 1 µF film capacitor into a 10 kΩ input impedance gives f_c = 15.92 Hz: at 20 Hz attenuation is −2.13 dB (+38.5° phase), and by 100 Hz response is virtually flat (−0.11 dB).

Frequently asked questions

What capacitor dielectric is best for audio AC coupling?

Polypropylene / polyester film capacitors or C0G ceramics avoid the voltage-dependent capacitance distortion caused by X7R/Y5V ceramics; for large >10 µF values, use audio-grade non-polar electrolytics.

Does the downstream amplifier input impedance change my high-pass cutoff?

Yes—enter the parallel combination of your bias resistor and the next stage’s input impedance as R, since both shunt AC signal to ground.

How long does an AC-coupled stage take to settle after power-on?

A 15.9 Hz filter has τ = 10 ms and settles to 99.3% in 5τ = 50 ms; ultra-low 1 Hz filters take ~0.8 seconds and may need a mute relay to avoid power-on thumps.