AVR 8MHz Internal RC Oscillator 9600 Baud UART Drift Calculator

Check whether an uncalibrated 8 MHz internal RC oscillator (±1% to ±3% tolerance) can sustain reliable 9600 or 38400 bps UART without a crystal.

Jump to results

Inputs

MCU clock & divider
Frame & oscillator budget
Crystal ~20–50 ppm; internal RC ~10,000 ppm (1%).

Results

Estimates
Baud rate timing error+0.16%
Actual synthesized baud
9,615.4 bps
Prescaler register
UBRR = 51 (div 52)
Ideal vs. actual divisor
52.083 → 52
Stop-bit worst-case drift
20.52% of 1 bit
Bit / frame duration
104 µs / 1,040 µs
Link margin screen
Pass (reliable)
Bit-timing & receiver sampling drift (10-bit frame)
ST D0 D1 D2 D3 D4 D5 D6 D7 SP Ideal center tick (dashed) vs. drifted RX sample dot (amber) Baud error: 0.16% · Stop-bit worst-case drift: 20.52% of 1 bit
Standard baud rates at this clock
Target bpsActual bpsRegisterError %Status
9,6009,615.4UBRR = 51 (div 52)+0.16%Pass (reliable)
19,20019,230.8UBRR = 25 (div 26)+0.16%Pass (reliable)
38,40038,461.5UBRR = 12 (div 13)+0.16%Pass (reliable)
57,60055,555.6UBRR = 8 (div 9)-3.55%Fail (framing error risk)
115,200125,000UBRR = 3 (div 4)+8.51%Fail (framing error risk)
230,400250,000UBRR = 1 (div 2)+8.51%Fail (framing error risk)
460,800500,000UBRR = 0 (div 1)+8.51%Fail (framing error risk)
921,600500,000UBRR = 0 (div 1)-45.75%Fail (framing error risk)

Keep single-side baud error under ±2.0% and total TX+RX stop-bit drift well below 45% of one bit period to prevent UART framing errors.

Budget total stop-bit drift when running UART without a crystal

Eliminating an external quartz crystal saves BOM cost and two MCU pins, but internal RC oscillators drift with temperature and supply voltage (commonly ±1% factory-calibrated, up to ±3–10% across extreme voltage/temperature corners).

At 8 MHz and 9,600 bps, UBRR = 51 introduces only +0.16% divider error, leaving almost the entire ±2% budget for RC drift—whereas 38,400 bps adds +0.16% or 57,600 bps adds −3.55% and fails rapidly.

Formulas

  • Osc error (%) = ppm ÷ 10,000 (10,000 ppm = 1.0%)
  • Worst-case combined = |Divider Error %| + 2 × Osc Error %
  • Stop-bit drift = Combined % × 9.5 bits (8N1)

Worked example

At 8 MHz with ±1% (10,000 ppm) RC tolerance and 9,600 bps, UBRR = 51 gives +0.160% divider error and 20.5% worst-case stop-bit drift (Pass). At ±3% RC, stop-bit drift exceeds 58% (Fail).

Frequently asked questions

How can I make internal RC UART reliable across −20 °C to +70 °C?

Keep baud rate at 9,600 or 19,200 bps, regulate VCC tightly (RC frequency shifts with voltage), or trim the OSCCAL register against a 32.768 kHz watch crystal or host break pulse.

Why does the stop-bit drift formula multiply oscillator tolerance by 2?

If both TX and RX use internal RC oscillators drifting in opposite directions (+1% and −1%), their relative clock mismatch doubles to 2%.

Does adding a second stop bit (8N2) forgive larger RC clock drift?

No—an extra stop bit adds idle time between bytes for receiver resynchronization, but it does not reduce accumulated drift across the first 9.5 bit times.