Worked calculation
- At 300 mm field width, image magnification is 7.2 ÷ 300 = 0.024×.
- The thin-lens working distance is 12 × (1 + 300 ÷ 7.2) = 512 mm. Vertical coverage is 300 × 5.4 ÷ 7.2 = 225 mm.
- 300 ÷ 2048 gives about 0.1465 mm/px before distortion, blur and calibration effects.
How the calculation works
Angle and crop factor
angle = 2 × atan(sensor side ÷ (2 × f)), crop = 43.27 mm ÷ sensor diagonalAngles assume a rectilinear lens at infinity. Multiply the focal length by diagonal crop for 35mm equivalence.
Working distance and sampling
WD = f × (1 + field width ÷ sensor width), mm/px = field size ÷ pixelsThe thin-lens distance is measured from the principal plane. Check the lens drawing before setting the physical mount distance.
Questions and answers
Can I place the mount exactly 512 mm above the conveyor?
The model measures from a principal plane inside the lens. Check the mechanical reference in the lens drawing and confirm with a target.
Is a 0.15 mm defect reliably detectable in this setup?
It covers about one pixel. Reliable inspection can require multiple pixels plus adequate contrast, lighting and lens resolution.