Worked calculation
- The tube adds about 12 ÷ 35 = 0.343×. Add the native 0.25× to get approximately 0.593×.
- Effective aperture is 4 × 1.593 ≈ f/6.37.
- Subject width is about 23.6 ÷ 0.593 = 39.8 mm.
How the calculation works
Magnification and clearance
M ≈ M₀ + extension ÷ f, subject distance ≈ f × (1 + 1 ÷ M)Subtract the lens-front offset from the modeled subject distance to estimate clearance. Internal focusing changes the effective focal length and geometry.
Effective aperture and diffraction
N effective = N × (1 + M), loss = 2 × log₂(1 + M), Airy diameter = 2.44 × λ × N effectiveThe aperture model assumes a pupil ratio of one. Two pixels is a sampling reference for the Airy disk diameter.
Questions and answers
Can I assume this 35mm lens stays near 0.59× at all focus-ring positions?
The estimate applies at the native 0.25× setting. Turning toward infinity changes the native contribution and can change effective focal length.
How can I check magnification after fitting the tube?
Photograph a millimeter scale square to the sensor. Divide the active sensor width by the width of the scale visible across the frame.