Worked example · Lighting falloff

200 W COB LED falloff from 2 m to 4 m

A 200 W COB with a fixed reflector measures 8000 lux at 2 m in this example. Move the same fixture to 4 m without changing its beam or dimmer.

See the worked calculation

Inputs

Results

Runs on your device

Target illuminance
2,000 lx
Stop loss at target
2 stops
Target illuminance
185.81 fc
Flash aperture at target
f/8
Flash reach at chosen aperture
4 m
Adjusted guide number
32 m
Inverse-square falloff
Illuminance from 8,000 lux at 2 m to 2,000 lux at 4 mREFERENCETARGET8,000 lx · 2 m2,000 lx · 4 m
The curve models the same source, beam and setting at different distances. Reference and target measurements are marked.

Worked calculation

  1. Distance doubles from 2 to 4 m, so the intensity ratio is (2 ÷ 4)² = 0.25.
  2. 8000 × 0.25 = 2000 lux, or about 185.8 foot-candles.
  3. One-quarter exposure is two stops lower. The fixture’s wattage does not appear in the ratio.

How the calculation works

Continuous light

E₂ = E₁ × (d₁ ÷ d₂)², stop loss = 2 × log₂(d₂ ÷ d₁)

Use matching units for both distances and retain the same beam configuration. One foot-candle is about 10.764 lux.

Direct flash

GN adjusted = GN₁₀₀ × √(ISO ÷ 100 × power fraction), N = GN adjusted ÷ distance

Convert distance to the guide-number unit before dividing. Use the manufacturer’s GN at your flash head zoom.

Questions and answers

Would 4 m still give 2000 lux if I swap the COB reflector?

Take a fresh measurement when the beam changes. The estimate scales readings from the same modifier and direction.

How much more light is needed at 4 m to match the 2 m reading?

Aim for four times the on-subject illuminance at 4 m. The dimmer scale may not map linearly to the measured output.