Worked example · Video storage

NAS storage for four 150 Mb/s cameras

Four cameras each send 150 Mb/s for three hours. Use an 8 TB usable NAS volume as the comparison, two copies, and reserve 15% across the total provisioning estimate.

See the worked calculation

Inputs

Enter 0 if unknown.
Count the primary plus any backups.

Results

Runs on your device

Recording time · one camera
6,044.44 min
Media write load
18.75 MB/s
Time · all cameras on one volume
1,511.11 min
Total per stream
150 Mb/s
Data per hour · one camera
67.5 GB
Aggregate ingest payload
600 Mb/s
Project footage
810 GB
Footage and copies
1,620 GB
Pool to provision with reserve
1,905.88 GB
Usable medium capacity
6,800 GB

Entered video bitrate.

Capacity allocation
Capacity 8,000 GB, projected footage 810 GBONE MEDIUM8,000 GBFOOTAGE810 GBFREE FOR FOOTAGE5,990 GBRESERVED1,200 GB
The bar shows one medium. Project footage spans all cameras and excludes the additional copies shown in the results.

Worked calculation

  1. Each camera writes 150 ÷ 8 = 18.75 MB/s. Four cameras sum to a 600 Mb/s incoming payload.
  2. 18.75 × 3.6 × 3 × 4 = 810 GB of footage. With a second copy this becomes 1620 GB.
  3. 1620 ÷ 0.85 ≈ 1905.88 GB of aggregate capacity keeps the requested reserve.

How the calculation works

Recording time and write load

MB/s = Mb/s ÷ 8, GB/h = MB/s × 3.6, minutes = usable GB ÷ GB/h × 60

Decimal GB is 10⁹ bytes. Binary GiB is 2³⁰ bytes. Use your camera’s measured or specified mode rate for critical media choices.

Multi-camera capacity

pool GB = GB/h × hours × cameras × copies ÷ (1 − reserve fraction)

The network value is payload only. Allow headroom for protocol overhead, rate peaks and actual media write performance.

Questions and answers

Can my 1 Gb/s port always handle four 150 Mb/s cameras?

600 Mb/s is only the incoming payload. Check bitrate peaks, protocol overhead, concurrent file transfers and what the NAS can write under load.

Is the second copy the same thing as RAID redundancy?

A separate copy is for recovery from events such as accidental deletion. RAID parity belongs in your usable storage calculation and serves a different purpose.