Worked calculation
- The rated factor gives (1 ÷ 125) × 1000 = 8.00 seconds.
- log₂(1000) ≈ 9.9658 stops. Exact 10 stops is 2¹⁰ = 1024×.
- The exact 10-stop setting is 1/125 × 1024 = 8.192 seconds.
How the calculation works
Apply the ND filter
t = t₀ × factor, factor = 2^stops = 10^densityA literal ND1000 factor gives 9.97 stops. An exact 10-stop filter multiplies time by 1024.
Correct film reciprocity
t corrected = t^P for t > 1 sApply the film exponent after the filter conversion. The ILFORD model uses the metered time directly at or below one second.
Questions and answers
Should my camera set 8 or 8.192 seconds for a nominal ND1000?
Use the nearest available setting and check the histogram or film meter. The literal difference is about 0.034 stop.
How do I check if my physical ND1000 is closer to 10 stops?
Meter with and without the filter in stable light. Divide the matched filtered shutter time by the unfiltered time to get the measured factor.