ASME VIII-1 / UG-28 SCREEN
Corrosion reduces vacuum capacity
A 48-inch vessel retains a 3/16-inch wall in a 120-inch bay after metal loss.
Inputs
Reset restores this worked example. View results ↑
Screening result
Edit inputs ↓ LiveThis elastic–yield interaction is a comparative screen. Confirm allowable pressure with UG-28 material charts and qualify each ring under UG-29/UG-30.
Calculation breakdown
- Outside diameter / net wall
- 256
- Unsupported length / diameter
- 2.5
- Ideal elastic buckling
- 29.061 psid
- Thin-wall hoop yield estimate
- 281.25 psid
- Elastic–yield critical pressure
- 26.339 psid
- Screening allowable pressure
- 8.78 psid
- Applied external differential
- 14.696 psid
- External pressure reserve
- -5.916 psid
- Full vacuum at standard atmosphere
- Fail screen
- Long-cylinder screening limit
- 1.249 psid
- Maximum screened support spacing
- 67.2989 in
- Added equal-bay supports within current span
- 1
- Spacing outcome
- Theoretical maximum
Worked calculation
A 48-inch vessel retains a 3/16-inch wall in a 120-inch bay after metal loss.
- Elastic–yield critical pressure
- 26.339 psid
- Screening allowable pressure
- 8.78 psid
- Added equal-bay supports within current span
- 1
The thin-shell pressure is strongly sensitive to wall thickness. The result shows the screened spacing for shorter effective bays.
Calculation basis
Elastic slenderness
Use the Windenburg–Trilling finite-length estimate and the thin long-ring ovalization asymptote. At long lengths the asymptote sets the lower bound of ideal elastic buckling.
Pe = max(2E(t/D)³/(1 − ν²), 2.42E(t/D)²·⁵/[(1 − ν²)⁰·⁷⁵(L/D − 0.45√(t/D))])Inelastic screen
Combine ideal elastic pressure with the approximate hoop yield pressure using a reciprocal interaction. Divide the result by the specified screening factor. A full vacuum uses 101.325 kPa differential.
Py = 2Sy·t/D · Pcrit = 1/(1/Pe + 1/Py) · Pa = Pcrit/SFStiffener spacing
Solve the same curve for the longest bay meeting demand. A dash can mean the long-shell limit suffices or that no span qualifies in model range. The spacing result assumes each line of support is effective.
Pa(Lmax) = Papplied
Comparative thin-shell screening for D/t ≥ 20 and L/D ≥ 0.2. UG-28 allowable pressure requires the project material A/B chart and correct unsupported length. Verify ovality, fabrication tolerances, heads, combined loads and ring inertia or attachment under UG-29/UG-30.