ASME B16.5 / APPENDIX 2

Hot Class 150 carbon steel flange

A Class 150 SA-105 flange is screened at 500°F with a 180 psig working pressure.

Inputs

Flange and operating point
°F
psig
Gasket and bolting
in
in
psi
in
TPI
ksi
%

Reset restores this worked example. View results ↑

Screening result

Edit inputs ↓ Live
FLANGE RATING 170 psig SEAT LOAD 46244.244 lbf BOLT PRELOAD 15636.002 lbf BOLT TORQUE 175.91 ft·lbf FLANGED JOINT Gasket + boltsP–T rating curveMetal temp. °F Flange rating headroom FAIL SCREEN 0% 100% LIMIT 150%+
180 psig demand / 170 psig limit

Verify flange, gasket and bolting compatibility. Nut-factor torque is an estimate for a specified assembly stress.

Export or share
Calculation breakdown
B16.5 material group
1.1
Working-pressure rating (B16.5-2020)
170 psig
Rating through 100°F
285 psig
Percent of cold rating
59.65 %
Pressure reserve
-10 psig
Tensile stress area per bolt
0.3345 in²
Pressure separating force
5,790.584 lbf
Operating gasket load Wm1
10,784.962 lbf
Gasket seating load Wm2
46,244.244 lbf
Controlling gasket load
46,244.244 lbf
Target preload per bolt
15,636.002 lbf
Total target bolt load
125,088.013 lbf
Target torque per bolt
175.91 ft·lbf
Governing comparison
Pressure rating
ORIGINAL PRESET

Worked calculation

A Class 150 SA-105 flange is screened at 500°F with a 180 psig working pressure.

Working-pressure rating (B16.5-2020)
170 psig
Pressure reserve
-10 psig
Governing comparison
Pressure rating

The temperature-derated rating is below working pressure. Increasing bolt preload does not increase the tabulated flange rating.

Calculation basis

  1. Pressure and temperature

    The B16.5-2020 customary table points are interpolated linearly in temperature. Metric results convert the same values to bar. F304 and F316 are Groups 2.1 and 2.2. F304L and F316L both use Group 2.3.

    Prating = Plo + (Phi − Plo)(T − Tlo)/(Thi − Tlo)

  2. Gasket demand

    Use effective gasket width b and reaction diameter G from the selected gasket and facing. Compare the larger of operating and seating loads with the total assembly target.

    Wm1 = πG²P/4 + 2πbGmP · Wm2 = πbGy

  3. Preload and torque

    Estimate the tensile area of a Unified thread from diameter and threads per inch. SI pitch converts the same thread geometry. Preload per bolt is stress area times target stress. Torque uses the specified nut factor and diameter.

    At = π(d − 0.9743/n)²/4 · T = K·d·F

Rating data cover 150, 300, 400, 600, 900 and 1500 for the shown grades. The customary range starts at −20°F and ends at 1,000°F for SA-105, F304 and F316, 800°F for F304L and 850°F for F316L. Confirm the intended edition, product form, flange geometry, gasket limits, stress at temperature, and PCC-1 assembly procedure.

Sources and verification scope ↗