ASME B16.5 / APPENDIX 2

F316 flange screened with low target preload

A Group 2.2 Class 600 flange has a smaller bolting set and a high gasket seating stress in this case.

Inputs

Flange and operating point
°F
psig
Gasket and bolting
in
in
psi
in
TPI
ksi
%

Reset restores this worked example. View results ↑

Screening result

Edit inputs ↓ Live
FLANGE RATING 1044 psig SEAT LOAD 1.27e5 lbf BOLT PRELOAD 5763.042 lbf BOLT TORQUE 54.03 ft·lbf FLANGED JOINT Gasket + boltsP–T rating curveMetal temp. °F Assembly load headroom FAIL SCREEN 0% 100% LIMIT 150%+
126,669.016 lbf demand / 46,104.334 lbf limit

Verify flange, gasket and bolting compatibility. Nut-factor torque is an estimate for a specified assembly stress.

Export or share
Calculation breakdown
B16.5 material group
2.2
Working-pressure rating (B16.5-2020)
1,044 psig
Rating through 100°F
1,440 psig
Percent of cold rating
72.5 %
Pressure reserve
634 psig
Tensile stress area per bolt
0.226 in²
Pressure separating force
13,189.663 lbf
Operating gasket load Wm1
30,501.095 lbf
Gasket seating load Wm2
126,669.016 lbf
Controlling gasket load
126,669.016 lbf
Target preload per bolt
5,763.042 lbf
Total target bolt load
46,104.334 lbf
Target torque per bolt
54.03 ft·lbf
Governing comparison
Gasket seating
ORIGINAL PRESET

Worked calculation

A Group 2.2 Class 600 flange has a smaller bolting set and a high gasket seating stress in this case.

Working-pressure rating (B16.5-2020)
1,044 psig
Gasket seating load Wm2
126,669.016 lbf
Total target bolt load
46,104.334 lbf

The class rating can clear pressure while nominal preload misses the gasket demand. The readout identifies the controlling comparison.

Calculation basis

  1. Pressure and temperature

    The B16.5-2020 customary table points are interpolated linearly in temperature. Metric results convert the same values to bar. F304 and F316 are Groups 2.1 and 2.2. F304L and F316L both use Group 2.3.

    Prating = Plo + (Phi − Plo)(T − Tlo)/(Thi − Tlo)

  2. Gasket demand

    Use effective gasket width b and reaction diameter G from the selected gasket and facing. Compare the larger of operating and seating loads with the total assembly target.

    Wm1 = πG²P/4 + 2πbGmP · Wm2 = πbGy

  3. Preload and torque

    Estimate the tensile area of a Unified thread from diameter and threads per inch. SI pitch converts the same thread geometry. Preload per bolt is stress area times target stress. Torque uses the specified nut factor and diameter.

    At = π(d − 0.9743/n)²/4 · T = K·d·F

Rating data cover 150, 300, 400, 600, 900 and 1500 for the shown grades. The customary range starts at −20°F and ends at 1,000°F for SA-105, F304 and F316, 800°F for F304L and 850°F for F316L. Confirm the intended edition, product form, flange geometry, gasket limits, stress at temperature, and PCC-1 assembly procedure.

Sources and verification scope ↗