ASME B16.5 / APPENDIX 2

F316L Class 900 at 825°F

A Group 2.3 F316L flange is screened at 825°F with a 900 psig working pressure.

Inputs

Flange and operating point
°F
psig
Gasket and bolting
in
in
psi
in
TPI
ksi
%

Reset restores this worked example. View results ↑

Screening result

Edit inputs ↓ Live
FLANGE RATING 1025 psig SEAT LOAD 46244.244 lbf BOLT PRELOAD 28318.531 lbf BOLT TORQUE 424.78 ft·lbf FLANGED JOINT Gasket + boltsP–T rating curveMetal temp. °F Flange rating headroom PASS SCREEN 0% 100% LIMIT 150%+
900 psig demand / 1,025 psig limit

Verify flange, gasket and bolting compatibility. Nut-factor torque is an estimate for a specified assembly stress.

Export or share
Calculation breakdown
B16.5 material group
2.3
Working-pressure rating (B16.5-2020)
1,025 psig
Rating through 100°F
1,800 psig
Percent of cold rating
56.94 %
Pressure reserve
125 psig
Tensile stress area per bolt
0.6057 in²
Pressure separating force
28,952.918 lbf
Operating gasket load Wm1
53,924.81 lbf
Gasket seating load Wm2
46,244.244 lbf
Controlling gasket load
53,924.81 lbf
Target preload per bolt
28,318.531 lbf
Total target bolt load
339,822.375 lbf
Target torque per bolt
424.78 ft·lbf
Governing comparison
Pressure rating
ORIGINAL PRESET

Worked calculation

A Group 2.3 F316L flange is screened at 825°F with a 900 psig working pressure.

Working-pressure rating (B16.5-2020)
1,025 psig
Pressure reserve
125 psig
Target preload per bolt
28,318.531 lbf

This point lies between the 800°F and 850°F F316L table rows. Verify the actual grade and applicable high-temperature material restrictions.

Calculation basis

  1. Pressure and temperature

    The B16.5-2020 customary table points are interpolated linearly in temperature. Metric results convert the same values to bar. F304 and F316 are Groups 2.1 and 2.2. F304L and F316L both use Group 2.3.

    Prating = Plo + (Phi − Plo)(T − Tlo)/(Thi − Tlo)

  2. Gasket demand

    Use effective gasket width b and reaction diameter G from the selected gasket and facing. Compare the larger of operating and seating loads with the total assembly target.

    Wm1 = πG²P/4 + 2πbGmP · Wm2 = πbGy

  3. Preload and torque

    Estimate the tensile area of a Unified thread from diameter and threads per inch. SI pitch converts the same thread geometry. Preload per bolt is stress area times target stress. Torque uses the specified nut factor and diameter.

    At = π(d − 0.9743/n)²/4 · T = K·d·F

Rating data cover 150, 300, 400, 600, 900 and 1500 for the shown grades. The customary range starts at −20°F and ends at 1,000°F for SA-105, F304 and F316, 800°F for F304L and 850°F for F316L. Confirm the intended edition, product form, flange geometry, gasket limits, stress at temperature, and PCC-1 assembly procedure.

Sources and verification scope ↗