ASME B16.5 / APPENDIX 2
F316L Class 900 at 825°F
A Group 2.3 F316L flange is screened at 825°F with a 900 psig working pressure.
Inputs
Reset restores this worked example. View results ↑
Screening result
Edit inputs ↓ LiveVerify flange, gasket and bolting compatibility. Nut-factor torque is an estimate for a specified assembly stress.
Calculation breakdown
- B16.5 material group
- 2.3
- Working-pressure rating (B16.5-2020)
- 1,025 psig
- Rating through 100°F
- 1,800 psig
- Percent of cold rating
- 56.94 %
- Pressure reserve
- 125 psig
- Tensile stress area per bolt
- 0.6057 in²
- Pressure separating force
- 28,952.918 lbf
- Operating gasket load Wm1
- 53,924.81 lbf
- Gasket seating load Wm2
- 46,244.244 lbf
- Controlling gasket load
- 53,924.81 lbf
- Target preload per bolt
- 28,318.531 lbf
- Total target bolt load
- 339,822.375 lbf
- Target torque per bolt
- 424.78 ft·lbf
- Governing comparison
- Pressure rating
Worked calculation
A Group 2.3 F316L flange is screened at 825°F with a 900 psig working pressure.
- Working-pressure rating (B16.5-2020)
- 1,025 psig
- Pressure reserve
- 125 psig
- Target preload per bolt
- 28,318.531 lbf
This point lies between the 800°F and 850°F F316L table rows. Verify the actual grade and applicable high-temperature material restrictions.
Calculation basis
Pressure and temperature
The B16.5-2020 customary table points are interpolated linearly in temperature. Metric results convert the same values to bar. F304 and F316 are Groups 2.1 and 2.2. F304L and F316L both use Group 2.3.
Prating = Plo + (Phi − Plo)(T − Tlo)/(Thi − Tlo)Gasket demand
Use effective gasket width b and reaction diameter G from the selected gasket and facing. Compare the larger of operating and seating loads with the total assembly target.
Wm1 = πG²P/4 + 2πbGmP · Wm2 = πbGyPreload and torque
Estimate the tensile area of a Unified thread from diameter and threads per inch. SI pitch converts the same thread geometry. Preload per bolt is stress area times target stress. Torque uses the specified nut factor and diameter.
At = π(d − 0.9743/n)²/4 · T = K·d·F
Rating data cover 150, 300, 400, 600, 900 and 1500 for the shown grades. The customary range starts at −20°F and ends at 1,000°F for SA-105, F304 and F316, 800°F for F304L and 850°F for F316L. Confirm the intended edition, product form, flange geometry, gasket limits, stress at temperature, and PCC-1 assembly procedure.