VESSEL GEOMETRY / STATIC LOADS

Horizontal vessel liquid volume & saddle load calculator

Calculate partial liquid volume, dipstick increments and empty, operating and hydrotest reactions at two saddles.

Inputs

Vessel and inventory
in
in
in
lb/gal
lb/gal
Metal and supports
in
in
lb/in³
lb
lb
in
in
in
lbf

Results update as inputs change. View results ↑

Screening result

Edit inputs ↓ Live
LIQUID VOLUME 761.34 US gal FULL CAPACITY 1253.373 US gal LEFT SADDLE 4358.815 lbf RIGHT SADDLE 4887.521 lbf LIQUID LEVEL & SUPPORTS Depth 28 inLeft saddleRight saddle Pier load headroom PASS SCREEN 0% 100% LIMIT 150%+
7,344.014 lbf demand / 10,000 lbf limit

Reactions are vertical static loads at standard gravity. Check saddle stresses, bearing, anchors and load combinations separately.

Export or share
Dipstick strapping table
Depth / D (%)Dipstick depth (in)Liquid volume (US gal)Capacity (%)
104.862.2174.96
209.6173.64313.85
3014.4311.69424.87
4019.2465.47437.14
5024626.68750
6028.8787.89962.86
7033.6941.67975.13
8038.41,079.7386.15
9043.21,191.15695.04
100481,253.373100
Calculation breakdown
Liquid volume at entered depth
761.34 US gal
Total capacity
1,253.373 US gal
Depth as percent of diameter
58.33 %
Liquid percent of capacity
60.74 %
Estimated empty mass
3,536.28 lb
Operating mass
9,246.34 lb
Hydrotest mass
13,977.36 lb
Left saddle, empty
1,613.597 lbf
Right saddle, empty
1,922.685 lbf
Left saddle, operating
4,358.815 lbf
Right saddle, operating
4,887.521 lbf
Left saddle, hydrotest
6,633.346 lbf
Right saddle, hydrotest
7,344.014 lbf
Saddle-to-saddle span
104 in
Reserve at governing pier
2,655.986 lbf

Calculation basis

  1. Depth to volume

    A circular segment times the tangent length gives the shell volume. Ellipsoid and hemisphere liquid fractions are exact cubic caps. The F&D profile is integrated along the axis over exact circular segments, with the crown and knuckle split at their tangent.

    V(h) = L·Asegment(h) + 2·Vhead(h)

  2. Weight cases

    Add ideal shell and head metal, centered accessories, and off-center accessories to form the empty mass. Operating mass adds the entered liquid inventory. Hydrotest mass adds the full volume of test water.

    Mop = Mempty + ρliquid·V(h) · Mtest = Mempty + ρwater·Vfull

  3. Saddle reactions

    Assume a level vessel and matching ends. The liquid, shell, heads and centered accessories act at mid-length. A positive accessory offset moves its mass toward the right saddle.

    RB = ΣWᵢ(xᵢ − xA)/(xB − xA) · RA = ΣWᵢ − RB

Strapping data cover ideal horizontal geometry at the entered dimensions, with zero volume at zero depth. Confirm surveyed tank geometry and calibration for inventory use. Saddle reactions exclude local stresses, anchors, flexure, and seismic or wind loads.

Sources and verification scope ↗