VESSEL GEOMETRY / STATIC LOADS
Full hydrotest governs the pier load
A 72-inch F&D vessel holds a light operating fluid. Both support piers have a 15,000 lbf input limit.
Inputs
Reset restores this worked example. View results ↑
Screening result
Edit inputs ↓ LiveReactions are vertical static loads at standard gravity. Check saddle stresses, bearing, anchors and load combinations separately.
| Depth / D (%) | Dipstick depth (in) | Liquid volume (US gal) | Capacity (%) |
|---|---|---|---|
| 10 | 7.2 | 172.14 | 5.01 |
| 20 | 14.4 | 477.602 | 13.91 |
| 30 | 21.6 | 855.294 | 24.9 |
| 40 | 28.8 | 1,276.011 | 37.15 |
| 50 | 36 | 1,717.178 | 50 |
| 60 | 43.2 | 2,158.345 | 62.85 |
| 70 | 50.4 | 2,579.062 | 75.1 |
| 80 | 57.6 | 2,956.753 | 86.09 |
| 90 | 64.8 | 3,262.216 | 94.99 |
| 100 | 72 | 3,434.356 | 100 |
Calculation breakdown
- Liquid volume at entered depth
- 1,348.684 US gal
- Total capacity
- 3,434.356 US gal
- Depth as percent of diameter
- 41.67 %
- Liquid percent of capacity
- 39.27 %
- Estimated empty mass
- 6,113.91 lb
- Operating mass
- 13,396.81 lb
- Hydrotest mass
- 34,723.41 lb
- Left saddle, empty
- 2,891.115 lbf
- Right saddle, empty
- 3,222.8 lbf
- Left saddle, operating
- 6,418.766 lbf
- Right saddle, operating
- 6,978.041 lbf
- Left saddle, hydrotest
- 16,748.84 lbf
- Right saddle, hydrotest
- 17,974.572 lbf
- Saddle-to-saddle span
- 128 in
- Reserve at governing pier
- -2,974.572 lbf
Worked calculation
A 72-inch F&D vessel holds a light operating fluid. Both support piers have a 15,000 lbf input limit.
- Left saddle, operating
- 6,418.766 lbf
- Right saddle, hydrotest
- 17,974.572 lbf
- Reserve at governing pier
- -2,974.572 lbf
Full water weight is greater than partial operating inventory. The margin compares each saddle in all three load cases.
Calculation basis
Depth to volume
A circular segment times the tangent length gives the shell volume. Ellipsoid and hemisphere liquid fractions are exact cubic caps. The F&D profile is integrated along the axis over exact circular segments, with the crown and knuckle split at their tangent.
V(h) = L·Asegment(h) + 2·Vhead(h)Weight cases
Add ideal shell and head metal, centered accessories, and off-center accessories to form the empty mass. Operating mass adds the entered liquid inventory. Hydrotest mass adds the full volume of test water.
Mop = Mempty + ρliquid·V(h) · Mtest = Mempty + ρwater·VfullSaddle reactions
Assume a level vessel and matching ends. The liquid, shell, heads and centered accessories act at mid-length. A positive accessory offset moves its mass toward the right saddle.
RB = ΣWᵢ(xᵢ − xA)/(xB − xA) · RA = ΣWᵢ − RB
Strapping data cover ideal horizontal geometry at the entered dimensions, with zero volume at zero depth. Confirm surveyed tank geometry and calibration for inventory use. Saddle reactions exclude local stresses, anchors, flexure, and seismic or wind loads.