ASME VIII-1 / UG-32 & UG-34
48-inch 2:1 ellipsoidal head
The head is a standard 2:1 inner profile at 225 psig with a 5% forming allowance and a 1/16-inch corrosion allowance.
Inputs
Reset restores this worked example. View results ↑
Screening result
Edit inputs ↓ LiveVerify forming and weld details. The volume and mass are for one ideal head to its tangent plane.
Calculation breakdown
- Pressure wall
- 0.271 in
- Minimum nominal wall
- 0.3511 in
- Net available wall
- 0.4125 in
- Available wall reserve
- 0.1415 in
- Inside dish depth
- 12 in
- One-head dish volume
- 62.669 US gal
- One-head steel weight
- 351.11 lb
- F&D M or flat C factor
- —
- New inside crown radius
- —
- New inside knuckle radius
- —
Worked calculation
The head is a standard 2:1 inner profile at 225 psig with a 5% forming allowance and a 1/16-inch corrosion allowance.
- Pressure wall
- 0.271 in
- Inside dish depth
- 12 in
- One-head dish volume
- 62.669 US gal
The ideal head depth is one quarter of the as-new diameter. Use corroded diameter for the pressure wall and the new tangent geometry for liquid volume.
Calculation basis
Formed heads
Size the 2:1 head using its corroded inside diameter and the hemisphere using its corroded inside crown radius. For F&D, use the Appendix 1-4 shape factor with both inside radii increased by the corrosion allowance. Check the new radii against the skirt OD and head wall.
t = PD/(2SE − 0.2P) · tF&D = PLM/(2SE − 0.2P) · M = (3 + √(L/r))/4Flat cover
Supply C for a verified unstayed attachment detail. This pressure-only case omits bolting moments and gasket forces.
t = d√(CP/SE)Geometry and allowances
Dish capacity uses the new inner profile to the tangent plane. Steel weight uses an ideal outer profile at the entered nominal wall and excludes the straight flange. The 2:1 outer ellipsoid approximates the true normal offset.
tnet = tnom(1 − forming loss) − CA
Use the project head-specific allowable stress. For F&D, apply the UG-32 torispherical stress limit and temperature reduction. Ellipsoidal and F&D heads with net wall-to-crown ratio below 0.002 need Mandatory Appendix 1-4(f). Verify formed minimum thickness, attachment detail, and external loading.