ASME VIII-1 / UG-32 & UG-34
Standard 6% flanged and dished head
A 48-inch ID F&D head uses the formed skirt OD as its new inside crown radius and 6% of that radius for the knuckle.
Inputs
Reset restores this worked example. View results ↑
Screening result
Edit inputs ↓ LiveVerify forming and weld details. The volume and mass are for one ideal head to its tangent plane.
Calculation breakdown
- Pressure wall
- 0.3246 in
- Minimum nominal wall
- 0.4075 in
- Net available wall
- 0.4719 in
- Available wall reserve
- 0.1473 in
- Inside dish depth
- 8.0306 in
- One-head dish volume
- 38.573 US gal
- One-head steel weight
- 353.15 lb
- F&D M or flat C factor
- 1.7606
- New inside crown radius
- 49.0687 in
- New inside knuckle radius
- 2.9441 in
Worked calculation
A 48-inch ID F&D head uses the formed skirt OD as its new inside crown radius and 6% of that radius for the knuckle.
- Pressure wall
- 0.3246 in
- One-head dish volume
- 38.573 US gal
- F&D M or flat C factor
- 1.7606
The shape factor brings M/2 to approximately 0.885. Compare the shallower tangent-plane volume and resulting thickness with a 2:1 ellipsoidal head.
Calculation basis
Formed heads
Size the 2:1 head using its corroded inside diameter and the hemisphere using its corroded inside crown radius. For F&D, use the Appendix 1-4 shape factor with both inside radii increased by the corrosion allowance. Check the new radii against the skirt OD and head wall.
t = PD/(2SE − 0.2P) · tF&D = PLM/(2SE − 0.2P) · M = (3 + √(L/r))/4Flat cover
Supply C for a verified unstayed attachment detail. This pressure-only case omits bolting moments and gasket forces.
t = d√(CP/SE)Geometry and allowances
Dish capacity uses the new inner profile to the tangent plane. Steel weight uses an ideal outer profile at the entered nominal wall and excludes the straight flange. The 2:1 outer ellipsoid approximates the true normal offset.
tnet = tnom(1 − forming loss) − CA
Use the project head-specific allowable stress. For F&D, apply the UG-32 torispherical stress limit and temperature reduction. Ellipsoidal and F&D heads with net wall-to-crown ratio below 0.002 need Mandatory Appendix 1-4(f). Verify formed minimum thickness, attachment detail, and external loading.