Worked example · Corrugated packaging

24 × 18 × 18 BC-Flute Double-Wall RSC Blank

A heavy article goes in a double-wall regular slotted container. The converter has given a preliminary quarter-inch addition to each scored panel dimension.

Purchasing blank area 21.9887 ft²

Edit this example

Results ↓
Box and board
in
in
in
in
in
Product and material
in
in
in
$/ft²
%

Spec sheet

PrintPackLab
Purchasing blank area
21.9887 ft²
Flat blank rectangle
86.75 × 36.5 in
Board for order
5,772.038 ft²
Material cost
$1,962.49 USD
Void fill envelope
2,144 in³
Flute caliper estimate
0.2559 in
Net panel outline
21.7669 ft²
Board test reference
48 ECT (48 lb/in edge crush)
RSC 0201 corrugated blankDashed: purchasing rectangle · Cyan: panel edges · Pink: joints RSC 0201 CORRUGATED BLANK 86.75 in36.5 in Dashed: purchasing rectangle · Cyan: panel edges · Pink: joints

Request a converter dieline and a physical box sample. Check board certificate, fit, compression and shipping specifications before ordering.

How these values are calculated
  1. The RSC blank spans two lengths, two widths and the joint. Its other dimension combines one box height and two half-width flaps. The rectangle is 86.75 × 36.5 in.
  2. The gross rectangle is 21.9887 ft² per box. Multiply by 250 boxes and add 5% for 5,772.038 ft² of board. At $0.34 per ft², the material estimate is $1,962.49.
  3. Subtract the product envelope of 5,632 in³ from the box’s inside 7,776 in³ to estimate up to 2,144 in³ of air space.

Worked calculation

  1. The RSC blank spans two lengths, two widths and the joint. Its other dimension combines one box height and two half-width flaps. The rectangle is 86.75 × 36.5 in.
  2. The gross rectangle is 21.9887 ft² per box. Multiply by 250 boxes and add 5% for 5,772.038 ft² of board. At $0.34 per ft², the material estimate is $1,962.49.
  3. Subtract the product envelope of 5,632 in³ from the box’s inside 7,776 in³ to estimate up to 2,144 in³ of air space.

The 86.75 × 36.5-inch model is a procurement estimate. The score allowance and 48 ECT reference both need confirmation for the chosen board.

Frequently asked questions

Does selecting BC flute automatically change the RSC score allowances?

The flute sets a nominal reference caliper. Enter the converter’s score allowance separately for the blank calculation.

What does 48 ECT describe on the double-wall reference?

It describes the board’s nominal edge crush rating in pounds per inch. Finished-box compression also depends on construction and conditioning.

Production checks and references

Pricing uses the bounding rectangle plus spoilage. The net area is a simplified panel outline before slot, tab and radius detailing. ECT and Mullen measure different properties.