ACI 318-19 §6.2 / §10.6 / §22.4

Concrete Column Axial Capacity Calculator

Compare tied and spiral concentric axial limits, gross reinforcement and weak-axis slenderness.

Edit inputs ↓

Inputs

Concentric axial ceiling · weak axis

Section
Frame & demand
φPn,max 822.49kip
kℓu/r 21.59 
Limit 31 
Steel ρg 1.76%
AnatomyDiagrammatic scale
Parameter-linked column drawing. Diagrammatic scale. WEAK-AXIS ELEVATIONP–M CONCEPTℓuPMφPn,maxAxial cap shown; curve schematicℓu 11 ftr 5.2 inkℓu/r 21.59

Screening

Within screening limits
Axial ceiling utilization85.1%
Tied confinement14.9% below the threshold
  • Concentric axial ceilingPu ≤ φPn,max
    Within limit
  • Gross steel ratio1% ≤ Ast/Ag ≤ 8% per §10.6.1.1
    Within limit
  • Slenderness screenkℓu/r at or below the weak-axis limit
    Within limit

The axial ceiling is one point on a column interaction diagram. Check actual eccentricity and P–M strength, reinforcement detailing and any second-order effects before using the section.

Calculation readout
QuantityValue
Design axial ceiling φPn,max822.49 kip
Weak-axis slenderness kℓu/r21.59
Slenderness threshold31
Gross longitudinal ratio1.76 %
Gross area Ag360 in²
Longitudinal steel area Ast6.32 in²
Weak-axis radius r5.196 in
Nominal concentric strength P₀1,581.71 kip
Nominal ceiling Pn,max1,265.37 kip
Compression factor φ0.65
Longitudinal yield used60 ksi

How the check works

Code basis ↗
  1. Compute Ag and P₀ = 0.85f′c(Ag − Ast) + fy Ast with fy limited to 80 ksi. Limit Pn to 0.80P₀ with φ = 0.65 for ties, or 0.85P₀ with φ = 0.75 for spirals.
  2. Screen 1–8% gross reinforcement. Use r = √(Ig/Ag) about the weak axis, then compare k lu/r with the threshold in §6.2.5.1.
  3. Enter M1/M2 as positive for single curvature and negative for double curvature. This is the reverse of the sign in §6.2.5.1, so the braced expression here is min(40, 34 − 12 M1/M2). The unbraced limit is 22.